Using the Monitor 133
01V96—Owner’s Manual
Monitoring
11
ESOLO TRIM
This parameter enables you to trim the level of the Solo signal in the range of –96 dB to
+12 dB.
FSOLO SAFE CHANNEL
For Mixdown Solo mode, Input Channels can be configured individually so that they
are not muted when other Input Channels are soloed (Solo Safe function). Signals from
Input Channels with the SOLO SAFE CHANNEL button turned on are always fed to the
Stereo bus, regardless of the channels’ Solo function status. You can clear all Solo Safe
settings by turning on the ALL CLEAR button.
GMONITOR TRIM
This parameter enables you to trim the level of the monitoring signal in the range of
–96 dB to +12 dB.
HMONO
This button switches the Monitor signal into mono.
Using the Monitor
1 Connect a monitoring system to the MONITOR OUT connectors.
To monitor the signal via headphones, connect headphones to the PHONES jack.
2Press the Monitor Source selector in the MONITOR section to select the mon-
itoring signal source.
To monitor the 01V96’s internal signals, turn off the selector (the button should be raised).
To monitor the signals at the 2TR IN connectors, turn on the selector (the button should be
pushed in).
3Adjust the monitoring level using the MONITOR [MONITOR LEVEL] control
while playing the sound sources.
To adjust the level of the monitoring signal via headphones, turn the [PHONES LEVEL]
control.
Tip: For example, if you set the internal effects processor’s return signal to Solo Safe, you can
monitor the soloed “processed (or wet)” signals.
PHONES
MONITOR
OUT
MONITOR
2TR IN
LEVEL
PHONES
LEVEL 010
010