York DJ150 Return Downflow Plenum With Panel, Discharge Panel In Place, Condensate Drain, Filters

Models: DJ150

1 52
Download 52 pages 10.45 Kb
Page 17
Image 17
FIGURE 13 - RETURN DOWNFLOW PLENUM WITH PANEL

035-19046-002-B-0104

FIGURE 13 - RETURN DOWNFLOW PLENUM WITH PANEL

FIGURE 14 - DISCHARGE PANEL IN PLACE

CONDENSATE DRAIN

The side condensate drain is reversible and maybe re-ori- ented to the rear of the cabinet to facilitate condensate pip- ing. A condensate drain connection is available through the base pan for piping inside the roof curb. Trap the connection per Figure 15. The trap and drain lines should be protected from freezing.

Plumbing must conform to local codes. Use a sealing com- pound on male pipe threads. Install condensate drain line from the 3/4 inch NPT female connection on the unit to an open drain.

OPTIONALCOIL

GUARD

3"Minimum

FIGURE 15 - CONDENSATE DRAIN

COMPRESSORS

The compressors are mounted on elastomer insulators. The mounting bolts have been fully tightened for shipping.

Do not loosen the compressor mounting bolts.

FILTERS

Two-inch filters are supplied with each unit. One-inch filters may be used with no modification to the filter racks. Filters must always be installed ahead of evaporator coil and must be kept clean or replaced with same size and type. Dirty fil- ters reduce the capacity of the unit and result in frosted coils or safety shutdown. All units use four (4) 20”x25”x2” filters. The unit should not be operated without filters properly installed.

Make sure that panel latches are properly positioned on the unit to maintain an airtight seal.

THERMOSTAT WIRING

The thermostat should be located on an inside wall approxi- mately 56 inch above the floor where it will not be subject to drafts, sun exposure or heat from electrical fixtures or appli- ances. Follow the manufacturer's instructions enclosed with thermostat for general installation procedure. Seven (7) color- coded, insulated wires should be used to connect the thermo- stat to the unit. Refer to Table 7 for control wire sizing and maximum length.

TABLE 7: CONTROL WIRE SIZES

Wire Size

Maximum Length*

18 AWG

150 Feet

 

 

*. From the unit to the thermostat and back to the unit.

POWER AND CONTROL WIRING

Field wiring to the unit, fuses, and disconnects must conform to provisions of National Electrical Code (NEC), ANSI/NFPA No. 70 – Latest Edition (in U.S.A.), current Canadian Electri- cal Code C221, and/or local ordinances. The unit must be electrically grounded in accordance with NEC and CEC as specified above and/or local codes.

Voltage tolerances which must be maintained at the com- pressor terminals during starting and running conditions are indicated on the unit Rating Plate and Table 1.

Unitary Products Group

17

Page 17
Image 17
York DJ150 Return Downflow Plenum With Panel, Discharge Panel In Place, Condensate Drain, Compressors, Filters