York DJ150 Installation Safety Information, Preceding Installation, Unit Shipping Bracket

Models: DJ150

1 52
Download 52 pages 10.45 Kb
Page 8
Image 8
INSTALLATION

035-19046-002-B-0104

TC

Technicoat Condenser Coil & Coil Guard

 

 

TD

Technicoat Condenser Coil & Dirty Filter Switch

 

 

TG

Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch

 

 

TJ

Technicoat Evaporator Coil

 

 

TL

Technicoat Evaporator Coil & Coil Guard

 

 

TM

Technicoat Evaporator Coil & Dirty Filter Switch

 

 

TQ

Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch

 

 

TS

Technicoat Evaporator & Condenser Coils

 

 

TU

Technicoat Evaporator & Condenser Coils & Coil Guard

 

 

TV

Technicoat Evaporator & Condenser Coils & Dirty Filter Switch

 

 

TY

Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch

 

 

INSTALLATION

INSTALLATION SAFETY INFORMATION

Read these instructions before continuing this appliance installation. This is an outdoor combination heating and cool- ing unit. The installer must assure that these instructions are made available to the consumer and with instructions to retain them for future reference.

1.Refer to the furnace rating plate for the approved type of gas for this furnace.

2.Install this furnace only in a location and position as specified on Page 11 of these instructions.

3.Never test for gas leaks with an open flame. Use com- mercially available soap solution made specifically for the detection of leaks when checking all connections, as specified on Pages 8, 24, 25 and 40 of these instruc- tions.

4.Always install furnace to operate within the furnace's intended temperature-rise range with the duct system and within the allowable external static pressure range, as specified on the unit name/rating plate, specified on Page 42 of these instructions.

5.This equipment is not to be used for temporary heating of buildings or structures under construction.

FIRE OR EXPLOSION HAZARD

Failure to follow the safety warning exactly could result in serious injury, death or property damage.

Never test for gas leaks with an open flame. use a commercially available soap solution made specifi- cally for the detection of leaks to check all connec- tions. A fire or explosion may result causing property damage, personal injury or loss of life.

PRECEDING INSTALLATION

1.Remove the two screws holding the brackets in the front, rear and compressor side fork-lift slots.

Bracket

Turn down

Screws

 

FIGURE 1 - UNIT SHIPPING BRACKET

8

Unitary Products Group

Page 8
Image 8
York DJ150 installation manual Installation Safety Information, Preceding Installation, Unit Shipping Bracket