Interfaces
Serial
Serial (RS-232) Connector
Pin No. | Description |
|
|
1 | Not used |
|
|
2 | RXD (receive data) input to the printer |
|
|
3 | TXD (transmit data) output from printer |
|
|
4 | DTR (data terminal ready) output from the printer |
| host may send data |
|
|
5 | Chassis ground |
|
|
6 | DSR (data set ready) input to the printer |
|
|
7 | RTS (request to send) output from the printer |
| condition when the printer is turned on |
|
|
8 | CTS (clear to send) input to the printer |
|
|
9 | +5 V @ 0.75 A fused |
|
|
The maximum current available through the serial and/or parallel port is not to exceed a total of 0.75 Amps.
When XON/XOFF handshaking is selected, data flow is controlled by the ASCII control codes DC1 (XON) and DC3 (XOFF). The DTR control lead will have no effect.
Interconnecting to DTE Devices
Interconnecting to DCE Devices
58 | LP |