Password Protection

Not the same as ID/Code. Password Protection blocks access to various low level printer adjustment screens (including this one). Check Use Password, then enter a password of your choice.

Start > Printers (or Printers and Faxes) > Right click Zebra P640i > Properties > Device Settings > Control > Advanced Utilites > Show Sensor data

Sensor Data

Ribbon Panel Detect: The current reading of the color ribbon sensor.

Panel Threshold: The current value of the detection threshold for the color ribbon. Above this value is termed “black,” below this value is termed “not black.”

Laminate Sensors: Reflective sensor that detect the

presence of laminate on the transfer rollers: below threshold = laminate present, above threshold = laminate absent.

Card presence Sensor: The reflective sensor to the right

of the card hopper: High = no card, Low = card present

Printhead Voltage: Should be about 24V.

AC Frequency: 50 or 60 Hz

Assumed AC Voltage: 110V assumed for 60 Hz. If frequency and voltage are not correct, see Laminate Station Adjust, TN6-5

Printhead Temperatue: Temperature ceiling 70°C (above that temperature, printing is stopped until the head cools).

Controller Board Temperature: Should be about 5° above ambient.

Heater Temperature: Temperatures at the top and bottom laminate heater cores.

Logic States: Summarizes all two-state interlocks and photosensors - a very useful diagnostic tool.

Printer Properties

Table 1: General

Start > Printers (or Printers and Faxes) > Right click Zebra P640i > Properties > General

Printing Preferences brings up the preferences screen, see Tech Note 8, Windows Printer Driver.

asPrintshownTestherePage. prints the standard Windows test page, cropped

Printer Properties

Table 1: Color

 

Management

 

 

Start > Printers (or Printers and Faxes) > Right click Zebra P640i > Properties > Color Management

Not currently supported

34

P640i Card Printer User Guide

980541-001 Rev. A