Set ID/Code: Sends an ID/Code (password of your choice) to the printer, synchronizing the
Disable Printer’s Print Button
In regular
Disable Printer’s Other Buttons
If Disable is checked, the RIBBON and LAMINATE buttons have no effect after the first downloaded job from the computer.
Status Polling Frequency
Determines how often the PC polls the printer for status:
•Normal (Default mode for Parallel and USB). Polls the printer for errors for as long as it is busy printing cards.
•Reduced (Default mode for Ethernet). Polls the printer for errors, sends a print job, polls twice more, then disconnects. This allows computers to connect to the printer and print a card while the previous card is printing, desirable in a network environment.
•None No error polling. Not a recommended option.
Number of Times to Retry
Determines how many retries the driver will execute in the event of a communications failure. The default is 3 retries. A higher number may be desirable if “Communications Failure” messages occur frequently.
Device Settings | Printer Adjustment |
|
|
Start > Printers (or Printers and Faxes) > Right click Zebra P640i > Properties > Device Settings > Printer
Adjustment
Print Station Adjust: see Tech Notes TN4 Print Station
Laminate Station Adjust: see Tech Notes TN6 Laminator
Flip Station Adjust: see Tech Notes TN5 Flip Station
Pick Position Adjust (Pixels): see Tech Notes TN2 Card Transport
Clean Frequency: see Tech Notes TN2 Card Transport
Advanced Adjust: see Tech Notes TN3 Magnetic Encoder
68 | P640i Card Printer User Guide |