Manual Calibration
A manual calibration should be performed whenever you are using
1.Turn on the printer power.
2.Remove
3.Press and hold the Feed button until the Error LED flashes once, then twice. Release the button.
4.The printer will set the media sensor for the label backing you are using. After it is done making this adjustment, the roll will automatically feed until a label is positioned at the printhead.
5.A profile of the media sensor settings will print (similar to the example in Figure 25). Upon completion, the printer will save the new settings in memory and the printer is ready for normal operation.
6.Press the Feed button. One entire blank label should feed. If this doesn’t happen, try defaulting (refer to “Feed Button Modes” in Troubleshooting) and recalibrating the printer.
NOTE: Performing a manual calibration disables the auto calibration function. To return to auto calibration, either default the printer (see “Feed Button Modes” in Troubleshooting) or refer to your label preparation software user’s manual.
NOTE: When using
software command (see your label preparation software user’s manual) before you perform a manual calibration.
Figure 25
28