Zenith L20V54S warranty Installer Menu, Accessing the Installer’s Menu, Using the Installer’s Menu

Models: L20V54S

1 64
Download 64 pages 20.54 Kb
Page 45
Image 45

Installer Menu

Use the Installer’s Menu to set up or change operational settings.

See more detailed descriptions of the Installer menu items on the following pages...

Accessing the Installer’s Menu

Make sure TV is on. Installer’s menu items can be accessed by using an installer’s remote control. Just press MENU repeatedly (at least 10 times) until the TV seems to stop responding, then press 9, 8, 7, 6, then ENTER to access the Installer’s menu. To remove the Installer’s menu, press ENTER again. Any changes you make will be stored in non- volatile memory. (The menu also disappears automatically.)

The Installer’s menu opens with item 000 INSTALLER SEQ 000. Use the Up/Down arrow keys to sequence through the available menu items. Or, access an item directly by keying in the line number, then pressing MENU. For example, to access the Sleep Timer option which is item 015, press 0-1-5, then MENU. To change a setting, use the Left/Right arrow keys. Or, enter a value directly.

Using the Installer’s Menu

Items 000 ~ 117 are immediately accessible only upon entering the Installer’s Menu. Their numbers, descriptions, ranges, factory default settings, and a place for listing any changes made on-site are given below and on the following pages.

Installer Menu Items 000 through 117

L20V54S PTC INSTALLER MENU

000

INSTALLER SEQ

000

 

 

 

UPN

000-000-000-000

FPGA 09F1

PTC V1.00.000

CPU V1.01.00

 

 

 

Typical Installer Menu

Menu Item

Function

Value Range

Default Value

Brief Description of Function and Comments

000

INSTALLER SEQ

0

~ 3

0

Leave default set to 0.

 

 

 

 

 

 

001

POWER MANAGE

0

~ 7

0

Sets number of hours of no activity before auto shut Off.

 

 

 

 

 

002

AC ON

0 / 1

0

Set to 1 to enable auto turn On at power up.

 

 

 

 

 

 

003

BAND/AFC

0

~ 3

1

Selects Tuning Band: 0=Broadcast, 1=CATV, 2=HRC, 3=IRC

 

 

 

 

 

004

STRT CHANNEL

0 ~ 127, 255

255

Channel at turn-on (Set 255 to return to last channel before power Off).

 

 

 

 

 

005

CHAN LOCK

0 / 1

0

If set to 1, cannot tune from current channel.

 

 

 

 

 

007

STRT VOLUME

0 ~ 63, 255

255

Sets Volume level at TV turn-on (Set 255 to retain last volume level).

 

 

 

 

 

008

MIN VOLUME

0 ~ 63

0

Sets minimum allowable volume setting.

 

 

 

 

 

009

MAX VOLUME

0 ~ 63

63

Sets maximum allowable volume setting.

 

 

 

 

 

010

MUTE DISABLE

0 / 1

0

Set to 1 to disable mute function.

 

 

 

 

 

011

KEY DEFEAT

0 / 1

1

Set to 1 to disable menu navigation keys on display panel.

 

 

 

 

 

012

IR BANKS EN.

0 / 1

0

Set to 1: enables TV to respond to IR code

 

 

 

 

 

013

SCAN MODE

0 / 1

1

Typically used for Hospitals: puts On-Off and FM in Ch Up/Down sequence.

 

 

 

 

 

014

STRT CH IN SM

0 / 1

0

Set to 1 to put TV on/off below start channel number.

 

 

 

 

 

015

SLEEP TIMER

0 / 1

1

Set to 1 to enable Sleep Timer.

 

 

 

 

 

016

EN TIMER

0 / 1

1

Set to 1 to enable On/Off Timers.

 

 

 

 

 

017

ALARM

0 / 1

1

Set to 1 to enable Alarm.

 

 

 

 

 

020

FEATURE LEVEL

0 / 1

1

Zen 1 Leave default set 1 (1 Zen 1)

 

 

 

 

 

021

V-CHIP

0 / 1

1

Set to 1 to enable V-Chip functions.

 

 

 

 

 

022

MAX BLK HRS

0 ~ 99

12

Sets number of V-Chip (Parental Control) blocking hours.

 

 

 

 

 

023

CAPTION LOCK

0 / 1

0

Set to 1 to retain caption setting at power Off.

 

 

 

 

 

 

025

FUNCTION PRE.

0

~ 3

1

Controls channel preview in Pay-Per-View function

 

 

 

 

 

 

027

HOSPITAL MODE

0

~ 2

2

Leave default set to 2.

 

 

 

 

 

028

CH. OVERIDE

0 / 1

1

If set to 0, limits direct access to favorite channels.

 

 

 

 

 

029

OLD OCV

0 / 1

0

Set to 1 to change M.P.I. operation to OCV.

 

 

 

 

 

030

ACK MASK

0 / 1

0

If set to 1, changes M.P.I. for some OCV boxes.

 

 

 

 

 

031

POLL RATE

20 ~ 169

94

Selects poll rate for M.P.I.

 

 

 

 

 

 

032

TIMING PULSE

186

~ 227

207

Sets baud rate for M.P.I.

 

 

 

 

 

 

P A G E 4 5

Page 45
Image 45
Zenith L20V54S warranty Installer Menu, Accessing the Installer’s Menu, Using the Installer’s Menu