Omni 56K Plus Series User’s Guide
Table
COMMAND | DESCRIPTION | VALUE |
|
|
|
| Only check 1D phase C data. | n=1 |
|
|
|
| Check both 1D and 2D phase C data. | n=2 |
|
|
|
+FCR=n | "Capability to receive" parameter |
|
|
|
|
| DCE will not receive message data or poll a remote device. | n=0 |
|
|
|
| DCE receives message data or polls a remote device. | n=1 |
|
|
|
+FDCC=vr,br,wd,ln,d | DCE capabilities parameters. |
|
f,ec,bf,st |
|
|
| Vertical resolution: Normal; 98 lpi. | vr=0 |
|
|
|
| Vertical resolution: Fine; 196 lpi. | vr=1 |
|
|
|
| Bit rate: 2400 bit/s; V.27ter. | br=0 |
|
|
|
| Bit rate: 4800 bit/s; V.27ter. | br=1 |
|
|
|
| Bit rate: 7200 bit/s; V.29 or V.17. | br=2 |
|
|
|
| Bit rate: 9600 bit/s; V.29 or V.17. | br=3 |
|
|
|
| Bit rate: 12000 bit/s; V.17. | br=4 |
|
|
|
| Bit rate: 14400 bit/s; V.17. | br=5 |
|
|
|
| Page width: 1728 pixels in 215mm. | wd=0 |
|
|
|
| Page width: 2048 pixels in 255mm. | wd=1 |
|
|
|
| Page width: 2432 pixels in 303mm. | wd=2 |
|
|
|
| Page length: A4; 297mm. | ln=0 |
|
|
|
| Page length: B4; 364mm. | ln=1 |
|
|
|
| Page length: unlimited length. | ln=2 |
|
|
|
| Data compression format: | df=0 |
|
|
|
| Data compression format: | df=1 |
|
|
|
| Error correction disabled. | ec=0 |
|
|
|
| Disable binary file transfer. | bf=0 |
|
|
|
| Minimum scan time/line: 0 ms. | st=0 |
|
|
|
| Minimum scan time/line: 5 ms. | st=1 |
|
|
|
| Minimum scan time/line:10 ms (normal); 5 ms (fine). | st=2 |
|
|
|
| Minimum scan time/line:10 ms. | st=3 |
|
|
|
| Minimum scan time/line:20 ms (normal); 10ms (fine). | st=4 |
|
|
|
| Minimum scan time/line:20 ms. | st=5 |
|
|
|
| Minimum scan time/line:40 ms (normal); 20ms (fine). | st=6 |
|
|
|
| Minimum scan time/line:40 ms. | st=7 |
|
|
|
+FDCS=vr,br,wd,ln,d | Current session parameter; refer to +FDCC command. |
|
f,ec,bf,st |
|
|
|
|
|
+FDIS=vr,br,wd,ln,df, | Current session negotiation parameter; refer to +FDCC command. |
|
ec,bf,st |
|
|
|
|
|
Command Sets |