Omni 56K Plus Series User’s Guide

Table 4-11 Service Class 2.0 Commands

COMMAND

DESCRIPTION

VALUE

 

 

 

 

 

nsr= 1:Non-standard frames are

 

 

reported.

 

 

 

+FIE=n

Procedure Interrupt parameter

n=0:Disable

 

 

n=1:Enable

 

 

 

+FPS=n

Page Transfer Status

n=1:Received page is good.

 

 

n=2:Page is bad; retrain is

 

 

requested.

 

 

n=3:Page is good; retrain is

 

 

requested.

 

 

n=4:Page is bad; procedure

 

 

interrupt is requested.

 

 

n=5:Page is good; procedure

 

 

interrupt is requested.

 

 

 

+FLO=n

Flow Control Select

n=0:No flow control

 

 

n=1:Sets XON/ XOFF software

 

 

flow control

 

 

n=2:Sets CTS/RTS hardware flow

 

 

control

 

 

 

+FPR=n

Serial Port Rate Control

n=0:Automatic DTE rate detection

 

 

by the DCE

 

 

n>0:Serial rate is fixed at the

 

 

value multiplied by 2400 bps.

 

 

 

+FBO=n

Phase C Data Bit Order

n=0:Selects direct bit order

 

 

n=1:Selects reversed bit order

 

 

 

+FEA=n

Phase C Received EOL alignment

n=0:EOL patterns are as received

 

 

 

+FCR=n

Capability to Receive

n=0:Not receive message data or

 

 

poll a remote device.

 

 

n=1: Receives message data or

 

 

poll a remote device.

+FCQ=<rq>,<tq>

Copy Quality disable/enable

rq= 0:Receive copy quality check

 

 

is disable.

 

 

rq=1:Receive copy quality check

 

 

is enable.

 

 

tq= 0:Transmit copy quality check

 

 

is disable.

 

 

tq=1:Transmit copy quality check

 

 

is enable.

+FRQ=pql,cbl

Receive Quality Thresholds

pgl= 0-64h:Specifies the

 

 

percentage of good lines

 

 

cbl= 0-ffh:Specifies the maximum

 

 

tolerable number of consecutive

 

 

bad lines.

 

 

 

Command Sets

4-15