Omni 56K Plus Series User’s Guide
Table
COMMAND | DESCRIPTION | VALUE |
|
|
|
|
| nsr= |
|
| reported. |
|
|
|
+FIE=n | Procedure Interrupt parameter | n=0:Disable |
|
| n=1:Enable |
|
|
|
+FPS=n | Page Transfer Status | n=1:Received page is good. |
|
| n=2:Page is bad; retrain is |
|
| requested. |
|
| n=3:Page is good; retrain is |
|
| requested. |
|
| n=4:Page is bad; procedure |
|
| interrupt is requested. |
|
| n=5:Page is good; procedure |
|
| interrupt is requested. |
|
|
|
+FLO=n | Flow Control Select | n=0:No flow control |
|
| n=1:Sets XON/ XOFF software |
|
| flow control |
|
| n=2:Sets CTS/RTS hardware flow |
|
| control |
|
|
|
+FPR=n | Serial Port Rate Control | n=0:Automatic DTE rate detection |
|
| by the DCE |
|
| n>0:Serial rate is fixed at the |
|
| value multiplied by 2400 bps. |
|
|
|
+FBO=n | Phase C Data Bit Order | n=0:Selects direct bit order |
|
| n=1:Selects reversed bit order |
|
|
|
+FEA=n | Phase C Received EOL alignment | n=0:EOL patterns are as received |
|
|
|
+FCR=n | Capability to Receive | n=0:Not receive message data or |
|
| poll a remote device. |
|
| n=1: Receives message data or |
|
| poll a remote device. |
+FCQ=<rq>,<tq> | Copy Quality disable/enable | rq= 0:Receive copy quality check |
|
| is disable. |
|
| rq=1:Receive copy quality check |
|
| is enable. |
|
| tq= 0:Transmit copy quality check |
|
| is disable. |
|
| tq=1:Transmit copy quality check |
|
| is enable. |
+FRQ=pql,cbl | Receive Quality Thresholds | pgl= |
|
| percentage of good lines |
|
| cbl= |
|
| tolerable number of consecutive |
|
| bad lines. |
|
|
|
Command Sets |