Omni 56K Plus Series User’s Guide

Table 4-12 Voice AT Commands

COMMAND

FUNCTION

OPTION

DEFAULT

DESCRIPTION

 

 

 

 

 

+VGR

Set the gain

0

0

0: Automatic gain control(AGC)

 

for the

 

 

 

 

received

 

 

 

 

voice sample.

 

 

 

 

 

 

 

 

+VGT

Set the gain

0-255

128

0: Silence

 

for the

 

 

1-255: The larger the value, the louder the

 

transmitted

 

 

 

 

 

voice will be.

 

voice sample.

 

 

 

 

 

 

 

 

 

 

 

+VLS

Select a voice

0,1, 2

0

0: The DCE is on hook. Local phone

 

I/O device.

 

 

connected to Telco line.

 

 

 

 

1: The DCE is on-hook and is connected to the

 

 

 

 

local phone. The local phone is also provided

 

 

 

 

with power. The modem can record/play

 

 

 

 

through the local phone set.

 

 

 

 

2: The DCE is off-hook and is connected to the

 

 

 

 

Telephone line. The local phone is provided

 

 

 

 

with power. The modem can record/play

 

 

 

 

through the local telephone line.

 

 

 

 

 

+VRA

Ring back

0 – 255

70

0: turn off the timer

 

goes away

 

 

1-255: Defines the period without ringback

 

timer

 

 

 

 

 

(after at lease one ringback has been

 

 

 

 

 

 

 

 

detected) in 100 -ms units.

 

 

 

 

 

+VRN

Ring back

0 – 255

10

0: turn off the timer

 

never come

 

 

1-255: Defines the period without ringback

 

timer

 

 

 

 

 

after dialing in 1 sec unit.

 

 

 

 

 

 

 

 

 

+VTX

Voice transmit

NA

NA

Switches to voice transmit mode.

 

mode

 

 

 

+VSD

Silence

Threshold,

15,70

Threshold:

 

detection

Period

 

0: Disable silence detection.

 

 

 

 

 

(0-255), (0-255)

 

1-255: The smaller the value, the more

 

 

 

 

 

 

 

 

sensitive to the silence detection it will be.

 

 

 

 

Period:

 

 

 

 

1-255: The required period of silence detection

 

 

 

 

before DCE reporting the silence event.

 

 

 

 

0: Disable silence detection.

 

 

 

 

Unit: 0.1 second

 

 

 

 

 

+VSM

Selection of

4;ZyXEL ADPCM;

4,9600

IMA 4 bit ADPCM.

 

compression

4 Bit;(9600)

 

Sample rate: 9600

 

method

 

 

 

 

 

 

+VTS=

Dual Tone

x: 0-3000 Hz

NA

x: first tone frequency

[x,y,z]

Generation

y: 0-3000 Hz

 

y: second tone frequency

 

 

 

 

 

z: 0- 1000(10ms)

 

z: duration in 10ms unit

 

 

 

 

 

+VTS=

DTMF Tone

x:0-9,*,#, A-D

NA

x: DTMF digits (0-9,*,#, A,B,C,D)

{x,y}

Generation

y:0-1000 (10ms)

 

y: duration in 10ms unit

 

 

 

 

 

 

 

 

Command Sets