Omni 56K Plus Series User’s Guide

Table 4-16 Extended S-Registers "ATSn=x"

COMMAND

BIT

DEC

HEX

FUNCTION AND DESCRIPTION

REF.

 

 

 

 

 

 

 

6-4

16-

10-70

Speaker volume control, increments of 32 in decimal

L0-7

 

 

112

 

value.

 

 

 

 

 

 

 

S25=

 

0-255

0-FF

Specify the time delay that DTR signal needs to be OFF

+000

 

 

 

 

before it will be recognized, in 10 ms units. If S25=0,

 

 

 

 

 

the delay time is set to 4 ms.

 

 

 

 

 

 

 

S27=

bit

dec

hex

Bit mapped register.

+156

 

 

 

 

 

 

 

0-2

 

 

Modem error control.

 

 

 

 

 

 

 

 

 

0

0

No error control.

&K0

 

 

 

 

 

 

 

 

1

1

MNP4 + MNP3 (see also S41.0)

&K1

 

 

 

 

 

 

 

 

2

2

MNP4 + MNP5 (see also S38.5, S41.0)

&K2

 

 

 

 

 

 

 

 

3

3

V.42+MNP4

&K3

 

 

 

 

 

 

 

 

4

4

V.42 + V.42bis (compatible with &K2) (Default)

&K4*

 

 

 

 

 

 

 

 

5

5

V.44

&K5

 

 

 

 

 

 

 

3-5

0

0

Flow control disabled.

&H0

 

 

 

 

 

 

 

 

24

18

Hardware (RTS/CTS) flow control. (Default)

&H3*

 

 

 

 

 

 

 

 

32

20

Software (XON/XOFF) flow control.

&H4

 

 

 

 

 

 

 

 

40

28

Reserved.

&H5

 

 

 

 

 

 

 

6-7

 

 

Signal quality.

 

 

 

 

 

 

 

 

 

0

0

No response to poor signal quality.

*Q0

 

 

 

 

 

 

 

 

64

40

Retrain action taken if signal quality is poor.

*Q1

 

 

 

 

 

 

 

 

128

80

Adaptive rate (auto fall-back /forward) when signal

*Q2*

 

 

 

 

quality changes. (Defaults)

S41.2

 

 

192

C0

Disconnect when signal quality is poor.

*Q3

 

 

 

 

 

 

S28=

bit

dec

hex

Bit mapped register.

+068

 

 

 

 

 

 

 

0

0

0*

Single line RJ-11 phone jack (Default)

&J0*

 

 

 

 

 

 

 

 

1

1

Multiple phone/modem line, RJ12/RJ13 phone jack

&J1

 

 

 

 

 

 

 

1

0

0*

Panel key is normal (Default)

*L0*

 

 

 

 

 

 

 

 

2

2

Panel key is locked

*L1

 

 

 

 

 

 

 

2-3

0

0

Destructive, expedited break.

&Y0

 

 

 

 

 

 

 

 

1

4

Non-destructive, expedited break. (Default)

&Y1*

 

 

 

 

 

 

 

 

10

8

Non-destructive, un-expedited break.

&Y2

 

 

 

 

 

 

 

4-5

0

0

No guard tone. (Default)

&G0*

 

 

 

 

 

 

 

 

16

10

Reserved

&G1

 

 

 

 

 

 

 

 

32

20

1800 Hz guard tone.

&G2

 

 

 

 

 

 

 

6

0

0

DTE/DCE rate follows link rate. (See also S18, S44b6)

&B0

 

 

 

 

 

 

 

 

64

40

DTE/DCE rate is fixed at the DTE setting, range from

&B1*

 

 

 

 

300-460.8 Kbps. (Default, also see S18, S44b6)

 

 

 

 

 

 

 

Command Sets

4-23