Omni 56K Plus Series User’s Guide

Table 4-16 Extended S-Registers "ATSn=x"

COMMAND

BIT

DEC

HEX

FUNCTION AND DESCRIPTION

REF.

 

 

 

 

 

 

 

0,1

0

0

Even parity

 

 

 

 

 

 

 

 

 

1

1

Odd parity

 

 

 

 

 

 

 

 

 

2

2

No parity

*

 

 

 

 

 

 

 

2

0

0

1 stop bit

*

 

 

 

 

 

 

 

 

4

4

2 stop bits

 

 

 

 

 

 

 

 

4,3

0

0

10 bit character length

*C0*

 

 

 

 

 

 

 

 

8

8

11 bit character length

*C1

 

 

 

 

 

 

 

 

16

10

9 bit character length

*C2

 

 

 

 

 

 

 

 

24

18

8 bit character length

*C3

 

 

 

 

 

 

 

7-5

0

0

Profile 0 as active settings after power on.

Z0

 

 

 

 

 

 

 

 

32

20

Profile 1 as active settings after power on.

Z1

 

 

 

 

 

 

 

 

64

40

Profile 2 as active settings after power on.

Z2

 

 

 

 

 

 

 

 

96

60

Profile 3 as active settings after power on

Z3

 

 

 

 

 

 

 

 

128

80

Factory default as active settings after power on

Z4*

 

 

 

 

 

 

S16=

 

dec

hex

Test status register.

+000

 

 

 

 

 

 

 

 

0

0

No test in progress.

&T0

 

 

 

 

 

 

 

 

1

1

Analog Loop-back test in progress.

&T1

 

 

 

 

 

 

 

 

3

3

Local Digital Loop-back test in process.

&T3

 

 

 

 

 

 

 

 

6

6

Remote Digital Loop-back test in process.

&T6

 

 

 

 

 

 

 

 

7

7

Remote Digital Loop-back with self-test in process.

&T7

 

 

 

 

 

 

 

 

8

8

Analog Loop back with self-test in progress.

&T8

 

 

 

 

 

 

S17=

bit

dec

hex

Bit-mapped register.

+022

 

 

 

 

 

 

 

4-1

0-30

0-1E

Set transmit power level from 0 to -15 dBm. (See also

*Pn

 

 

 

 

S35b3) (Default *P11)

 

 

5

0

0

Normal dial. (Default)

D

 

 

 

 

 

 

 

 

32

20

Reverse dial, go on-line in answer mode.

DR

 

 

 

 

 

 

 

7, 6

0

0

AT Commands set

*I0*

 

 

 

 

 

 

 

 

64

40

V.25bis command set

*I1

 

 

 

 

 

 

 

 

128

80

Dumb mode (no command accepted)

*I2

 

 

 

 

 

 

S18=

 

dec

hex

Force modem to fix baud rate when answering.

+000

 

 

 

 

 

 

 

 

0

0

Disable fixed baud function.

*

 

 

 

 

 

 

 

 

1-46

1-2E

Enable baud rate to be fixed when answering. Baud

 

 

 

 

 

rate value settings (n) the same as S20

 

 

 

 

 

 

 

S19=

 

dec

hex

Modem connection mode, same

+000/&Nn

 

 

 

 

Setting value as 'AT&Nn' command.

 

 

 

0-99

0-63

 

 

 

 

 

 

 

S20=

 

dec

hex

DTE speed (bps). Auto detected from AT Command.

+001

 

 

 

 

 

 

4-20

Command Sets