Omni 56K Plus Series User’s Guide
Table
COMMAND | DESCRIPTION | VALUE |
|
|
|
|
|
|
+FDR | Receive phase C data command; initiates document reception. |
|
|
|
|
+FDT=df,vr,wd, ln | Transmit phase C data command: release the DCE to proceed with |
|
| negotiation. |
|
|
|
|
+FET=n | End of page or document command: |
|
|
|
|
| More pages; same document. | n=0 |
|
|
|
| End of document; another document follows. | n=1 |
|
|
|
| No more pages or documents. | n=2 |
|
|
|
| Procedure interrupt; another page follows. | n=4 |
|
|
|
| Procedure interrupt; end of document, another document follows. | n=5 |
|
|
|
| Procedure interrupt; end of document. | n=6 |
|
|
|
+FK | Regular fax abort command. |
|
|
|
|
+FLID="string" | Local ID string parameter. |
|
|
|
|
+FLO=n | Flow control options: |
|
|
|
|
| No flow control. | n=0 |
|
|
|
| Set XON/XOFF software flow control. | n=1 |
|
|
|
| Set CTS/RTS hardware flow control. | n=2 |
|
|
|
+FLPL=n | Document for polling command: |
|
|
|
|
| The DTE has no document available for polling. | n=0 |
|
|
|
| Indicate a document available for polling. | n=1 |
|
|
|
+FMDL? | Request DCE model. |
|
|
|
|
+FMFR? | Request DCE manufacturer. |
|
|
|
|
+FMINSP=n | Minimum phase C speed parameter: |
|
|
|
|
| 2400 bps. | n=0 |
|
|
|
| 4800 bps. | n=1 |
|
|
|
| 7200 bps. | n=2 |
|
|
|
| 9600 bps. | n=3 |
|
|
|
| 12000 bps. | n=4 |
|
|
|
| 14400 bps. | n=5 |
|
|
|
+FPHCTO= | DTE Phase C response | |
<value> | Determine how long the DCE will wait for a command after reaching |
|
| the end of data when transmitting in Phase C. |
|
| <value>=0 to 255; 100 ms units. |
|
+FPTS=n | Page transfer status |
|
|
|
|
| Received page good. | n=1 |
|
|
|
| Page bad; retrain requested. | n=2 |
|
|
|
| Page good; retrain requested. | n=3 |
|
|
|
Command Sets |