Omni 56K Plus Series User’s Guide

Table 4-16 Extended S-Registers "ATSn=x"

COMMAND

BIT

DEC

HEX

FUNCTION AND DESCRIPTION

REF.

 

 

 

 

 

 

 

S46=

 

 

dec

hex

CND silence detection interval.

+028

 

 

 

 

 

 

 

 

 

 

0-255

0-FF

To process the CND, silence must be detected for the

 

 

 

 

 

 

specified interval, in 20 ms units.

 

 

 

 

 

 

 

 

S48=

 

bit

dec

hex

Bit-mapped register.

+000

 

 

 

 

 

 

 

 

 

0

1

1

Cause CND information to be reported in raw format.

 

 

 

 

 

 

 

 

 

 

2

4

4

Enable data calling tone (CNG) sending.

 

 

 

 

 

 

 

 

 

 

3

8

8

Reverse the V.23 channel speed. Originate mode

&N12

 

 

 

 

 

modem speed (Send/Receive) 1200/75; Answer mode

 

 

 

 

 

 

modem speed (Send/Receive) 75/1200.

 

 

 

 

 

 

 

 

 

 

4

16

10

(Work with &D1 command) DTR ON will have the

 

 

 

 

 

 

modem dial the default number and DTR OFF will have

 

 

 

 

 

 

the modem hang-up and reset to profile 0. When the

 

 

 

 

 

 

modem is idle (waiting for command), it will not dial any

 

 

 

 

 

 

number when DTR changes from ON to OFF.

 

 

 

 

 

 

 

 

S49=

 

bit

dec

hex

Bit-mapped register

+006

 

 

 

 

 

 

 

 

 

7

0

0

For cellular mode only. Modem is installed in office

*

 

 

 

 

 

(Default)

 

 

 

 

128

80

For cellular mode only. Modem is connected to a mobile

 

 

 

 

 

 

phone

 

 

 

 

 

 

 

 

S52=

 

bit

dec

hex

Bit-mapped register.

+000

 

 

 

 

 

 

 

 

 

7

0

0

Select ‘Mark’ as the first signal of the V.23 handshaking

&N12

 

 

 

 

 

sequence. (Default)

 

 

 

 

128

80

Select ‘Space’ as the first signal of the V.23

&N12

 

 

 

 

 

handshaking sequence.

 

 

 

 

 

 

 

 

S56=

 

 

dec

hex

 

+000

 

 

 

 

 

 

 

 

 

 

0-255

0-FF

Hook flash detect time, in units of 10ms. A value of zero

 

 

 

 

 

 

use country-specific default duration.

 

S57=

 

bit

dec

hex

Bit-mapped register.

+016

 

 

 

 

 

 

 

 

 

4

16

10

Enables the reporting of Class 1 capability in the

 

 

 

 

 

 

response to +FCLASS=?

 

 

 

 

 

 

 

 

 

 

6

0

0

Disabled busy detection when dialing is proceeding

 

 

 

 

 

 

(Default)

 

 

 

 

64

40

Enables busy detection in dialing period

 

 

 

 

 

 

 

 

 

 

 

Bit

S-register bit number, 'b', used in 'ATSr.b=n' and 'ATSr.b=?'

 

 

 

 

dec

Decimal value, 'x', used in 'ATSn=x'

 

 

 

 

hex

Equivalent Hexadecimal value.

 

 

 

 

+nnn

Factory default when listed in 'Reference' column.

 

 

 

 

Note:

'AT' is omitted when an AT command is referred to in the 'Reference' column.

 

 

 

 

 

 

 

 

4-26

Command Sets