Omni 56K Plus Series User’s Guide

 

 

 

Table 4-10 Class 2 Command Responses

 

 

 

 

 

 

 

RESPONSE

VALUE

FUNCTION AND DESCRIPTION

 

 

 

 

 

 

 

+FPOLL

 

Remote polling indication.

 

 

 

 

 

 

 

+FPTS:n

 

Receive page transfer status response; refer to +FPTS=n

 

 

 

 

command.

 

 

 

 

 

 

 

+FTSI:"string"

 

Report remote ID response TSI.

 

 

 

 

 

 

 

+FVOICE

 

Transition to Voice response.

 

 

 

 

 

 

Class 2 Flow Control

Flow control is necessary to match the DTE-DCE data rate to the line-signaling rate while transmitting or receiving Group 3 (T.4) data. In Class 2 fax mode, both hardware (RTS/CTS) and software (XON/XOFF) flow control are enabled.

4.2.3 Service Class 2.0 Commands

Table 4-11 Service Class 2.0 Commands

COMMAND

DESCRIPTION

VALUE

 

 

 

ATD

Dial and originate a call

 

 

 

 

ATA

Answer a call

 

 

 

 

+FDT

Transmit phase C data command: releases

 

 

the DCE to proceed with the negotiation.

 

 

 

 

+FDR

Receive phase C data command: initiates

 

 

document reception.

 

 

 

 

+FKS

Terminate a Session, orderly fax abort.

 

 

 

 

+FIP

Initialize Service Class 2.0 Parameters.

 

 

 

 

+FCLASS=n

Service Class Identification and Control

n=0,1,2.0,8;refer to the +FCLASS

 

 

Class 1 command

+FMI?

Identify DCE Manufacturer

ZyXEL

 

 

 

+FMM?

Identify DCE

Omni 56K Plus

 

 

 

+FMR?

Identify DCE Revision

Vx.x

 

 

 

+FCC=vr,br,wd,ln,df,ec,bf,st

Establish DCE Capabilities

 

 

 

 

 

Vertical Resolution

vr=0:Normal;98 lpi

 

 

vr=1:Fine;196 lpi

 

 

 

 

Bit Rate

br=0:2400 bps

 

 

br=1:4800 bps

 

 

br=2:7200 bps

 

 

br=3:9600 bps

 

 

br=4:12000 bps

 

 

br=5:14400 bps

 

 

 

Command Sets