Omni 56K Plus Series User’s Guide
4.6S-Register Descriptions
In most
COMMAND | FUNCTION & DESCRIPTION | +REF. |
|
|
|
S0= | Sets the number of rings on which the modem will answer. 0 value disables | +000 |
|
| |
S1= | Counts and stores number of rings from an incoming call. | +000 |
|
|
|
S2= | Defines escape code character, default ‘+’ (43 dec.). A value of | +043 |
| disables the escape code. |
|
|
|
|
S3= | Defines ASCII Carriage Return. | +013 |
|
|
|
S4= | Defines ASCII Line Feed. | +010 |
|
|
|
S5= | Defines ASCII Backspace. A value of | +008 |
| delete function. |
|
|
|
|
S6= | Sets the number of seconds the modem waits before dialing if ‘X0’ or ‘X1’ is | +003 |
| selected. If a setting of ‘X2,’ ‘X7’ is selected, the modem will dial as soon as it |
|
| detects a dial tone. This register also sets the |
|
| modifier to wait for the dial tone. (See also S41b4) |
|
|
|
|
S7= | Sets duration, in number of seconds modem waits for a carrier. | +060 |
|
|
|
S8= | Sets duration, in seconds, for pause (,) option in Dial command and pause | +002 |
| between command |
|
|
|
|
S9= | Sets duration, in tenths of a second of remote carrier signal before recognition. | +006 |
| (Ignored if in |
|
|
|
|
S10= | Sets duration, in tenths of a second, modem waits after loss of carrier before | +007 |
| hanging up. |
|
|
|
|
S11= | Sets duration and spacing, in milliseconds, of dialed | +070 |
|
|
|
COMMAND | BIT | DEC | HEX | FUNCTION AND DESCRIPTION | REF. |
|
|
|
|
|
|
S13= | bit | dec | hex | +000 | |
|
|
|
|
|
|
| 1 | 2 | 2 | Capture modem manufacturer information during V.42 |
|
|
|
|
| handshake, can be displayed at ATI2 <Last |
|
|
|
|
| Speed/Protocol> line if available (‘Flash’ or ‘ ZyXEL’ |
|
|
|
|
| stands for ZyXEL connection) |
|
|
|
|
|
|
|
S14= | bit | dec | hex | +002 | |
|
|
|
|
|
|
| 1 | 0 | 0 | Grant Remote Digital | &T4 |
|
|
|
|
|
|
|
| 2 | 2 | Deny Remote Digital | &T5* |
|
|
|
|
|
|
S15= | bit | dec | hex | +066 | |
|
|
|
|
|
|
Command Sets |