Omni 56K II and Omni 56K Plus II User’s Guide

RESPONSE

VALUE

FUNCTION AND DESCRIPTION

 

 

 

 

 

command.

 

 

 

+FTSI:"string"

 

Report the remote ID response TSI.

 

 

 

+FVOICE

 

Changes to voice response.

 

 

 

Class 2 Flow Control

Flow control is necessary to match the DTE-DCE data rate to the line-signaling rate while transmitting or receiving Group 3 (T.4) data. In Class 2 fax mode, both hardware (RTS/CTS) and software (XON/XOFF) flow control are enabled.

5.2.3Service Class 2.0 Commands

Table 5-11 Service Class 2.0 Commands

COMMAND

DESCRIPTION

VALUE

 

 

 

+FDT

Transmit a phase C data command.

 

 

This command releases the DCE to

 

 

proceed with the negotiation.

 

+FDR

Receive a phase C data command.

 

 

This command initiates document

 

 

reception.

 

+FKS

Terminates a Session, orderly fax

 

 

abort.

 

 

 

 

+FIP

Initialize the Service Class 2.0

 

 

Parameters.

 

 

 

 

+FCLASS=n

Service Class Identification and Control

n=0,1,2.0,8;refer to the

 

 

+FCLASS Class 1 command

+FMI?

Identify DCE Manufacturer

ZyXEL

 

 

 

+FMM?

Identify DCE

Omni 56K II/Omni 56K Plus II

 

 

 

+FMR?

Identify DCE Revision

Vx.x

 

 

 

+FCC=vr,br,wd,In,df,ec,bf,st

Establish DCE Capabilities

 

 

 

 

 

Vertical Resolution

vr=0:Normal;98 lpi

 

 

vr=1:Fine;196 lpi

5-18

Command Sets