Omni 56K II and Omni 56K Plus II User’s Guide

COMMAND

BIT

DEC

HEX

FUNCTION AND DESCRIPTION

REF.

 

 

 

 

 

 

 

7

128

80

Ignore calling tone, not to be used as fax detection.

 

 

 

 

 

 

 

S42=

bit

dec

hex

Bit-mapped register.

 

 

 

 

 

 

 

 

1

2

2

Enables throughput averaging.

2

 

 

 

 

 

 

 

2

4

4

A CND message forces on even if ATQ2 is set.

 

 

 

 

 

 

 

 

3

8

8

This disables the escape sequence code in answer

 

 

 

 

 

mode.

 

 

4

16

10

This disables the V.17 14,400 Fax in calling mode and

 

 

 

 

 

no effect on answering mode.

 

 

 

 

 

 

 

 

6

64

40

This disables the 'RINGING' result code.

Xn

 

 

 

 

 

 

 

7

128

80

The DCD is forced on but pulses off for 0.5 second at

&C0

 

 

 

 

carrier loss.

 

S43=

bit

dec

hex

Bit-mapped register.

+008

 

 

 

 

 

 

 

6

64

40

Enable a 1.5 second pause between off-hook and

 

 

 

 

 

modem answering.

 

 

 

 

 

 

 

 

7

128

80

The modem hangs-up if the line condition does not

 

 

 

 

 

permit the modem to run at the highest speed set by

 

 

 

 

 

'&Nn' command.

 

S44=

bit

dec

hex

Bit-mapped register.

+000

 

 

 

 

 

 

 

3

8

8

ATDSn initiates auto-dial of the stored numbers

DSn

 

 

 

 

consecutively until a connection is made (cyclic dial).

 

 

 

 

 

 

 

 

4

16

10

DSR follows DTR (see also S41.5).

&S1

 

 

 

 

 

 

 

6

64

40

When selected with ‘&B0’, DTE speed is fixed at

&Bn

 

 

 

 

38400 when the link speed is above 9600. DTE speed

 

 

 

 

 

is fixed at 9600 if the link speed is 7200. If it is below

 

 

 

 

 

7200, the DTE speed follows link speed. When

 

 

 

 

 

selected with &B1, DTE speed is fixed at the current

 

 

 

 

 

rate when an ARQ connection is made. When a non-

 

 

 

 

 

ARQ connection is made, DTE speed follows the link

 

 

 

 

 

speed (See also S18).

 

S45=

 

dec

hex

The delay during which the CND silence detection is

+100

 

 

0-255

0-FF

disabled, in 20 ms units (see also S46).

 

 

 

 

 

 

 

S46=

 

dec

hex

The CND silence detection interval.

+028

 

 

 

 

 

 

Command Sets

5-33