Omni 56K II and Omni 56K Plus II User’s Guide

COMMAND

DESCRIPTION

VALUE

 

 

 

+FCR=n

Capability to Receive

n=0: Do not receive message

 

 

data or poll a remote device.

 

 

n=1: Receives message data or

 

 

polls a remote device.

 

 

 

+FCQ=<rq>,<tq>

Copy Quality disable/enable

rq= 0:Receive copy quality

 

 

check is disabled.

 

 

rq=1:Receive copy quality

 

 

check is enabled.

 

 

tq= 0:Transmit copy quality

 

 

check is disabled.

 

 

tq=1:Transmit copy quality

 

 

check is enabled.

+FRQ=pql,cbl

Receive Quality Thresholds

pgl= 0-64h:Specifies the

 

 

percentage of good lines

 

 

cbl= 0-ffh:Specifies the

 

 

maximum tolerable number of

 

 

consecutive bad lines.

 

 

 

+FAA=n

Adaptive Answer Mode

n=0:Answers as set by

 

 

+FCLASS

 

 

n=1:Answers and automatically

 

 

determines the call type.

 

 

 

+FCT=n

Phase C Timeout

n=0-ffh,1 sec units

 

 

 

+FMS=n

Minimum Phase C Speed

n=0:2400 bps

 

 

n=1:4800 bps

 

 

n=2:7200 bps

 

 

n=3:9600 bps

 

 

n=4:12000 bps

 

 

n=5:14400 bps

 

 

 

+FBS?

Buffer Size

512,256

 

 

 

Command Sets

5-21