INSTALLATION

B. Planning the installation

Charging station

First and foremost the charging station should be posi- tioned:

Centrally in the main area, along the outer edge and with a large free area in front of the station.

3012-233

In the shadow. The battery is spared if it charged in the low possible ambient temperature.

On relatively level ground. The height difference must not differ more than 10 cm between the front and rear of the charging station.

Max 10 cm

Max 10 cm

3012-296

Close to a wall socket:

The charging station should be connected to a 230 V wall socket via the low voltage cable and transformer.

The supplied low voltage cable is 20 metres long.

IMPORTANT INFORMATION

The length of the low voltage cable must not be changed.

3012-220

3012-223

The transformer must be placed where it is well ventilated and is not exposed to direct sunlight. It is also beneficial if the transformer can be placed under a roof.

It is recommended to use an earth fault-breaker when connecting the transformer to the wall socket.

English-15

Image 14
Contents Auto Mower Auto Mower Helpdesk Congratulations IntroductionIntroduction Symbols on the Auto Mower SymbolsSymbols Symbols in the Operator’s Manual Xxxxxx xxx xxxx xxxxxxx xxx xxxx xxxx xxxxxUse Safety InstructionsSafety Instructions Maintenance TransportPresentation PresentationFunction Auto Mower Working methodEnglish-11 Capacity Movement patternPreparations InstallationInstallation Auto Mower, what is what? Numbers in the picture corresponds toLength of the low voltage cable must not be changed Planning the installationCharging station English-16 English-17 Boundary wire 10 cm Minimise Placing the charging station Charging the battery Laying out the boundary wireConnecting the boundary wire English-24 Checking the installation Linking the Auto Mower to the charging stationControl Panel Control panelShortcuts ProgramNumbers Main switchSelect Main menu Menu FunctionsMenu functions Commands TimerTimer override Drive past wire InstallationCharge exit settings Garden shapeDrive past wire Garden shape Check loop Charge exit settings Settings PIN code Sounds Significance Starting Charging Security Sounds User info level Use Charging a discharged batteryUSE Starting the Auto MowerRestart Using the timerStopping the Auto Mower Turn off Auto MowerAdjusting the cutting height Battery MaintenanceMaintenance Winter StorageBody CleaningUnderframe and blade disc Replacing the blade units Fault messages Trouble ShootingTrouble shooting Empty battery Fault message Cause Action OutsideLow battery voltage Wrong PIN codeTrouble Shooting Guide Technical Data Technical DataEU Declaration of Conformity only applies to Europe EU Declaration of ConformityEU declaration of conformity 114 01 2003W23Also See