Guidance and manufacturer’s declaration – electromagnetic immunity (continued)

The AutoSet CS2 is intended for use in the electromagnetic environment specified below. The customer or the user of the AutoSet CS2 should assure that it is used in such an environment.

Immunity test

IEC60601-1-2

Compliance

Electromagnetic environment – guidance

test level

level

 

 

 

 

 

 

 

 

 

Portable and mobile RF communications

 

 

 

equipment should be used no closer to any part

 

 

 

of the AutoSet CS2, including cables, than the

 

 

 

recommended separation distance calculated

 

 

 

from the equation applicable to the frequency of

 

 

 

the transmitter.

 

 

 

Recommended separation distance

Conducted RF

3 Vrms

3 Vrms

d = 1.17 √P

IEC 61000-4-6

150 kHz to 80 MHz

 

 

Radiated RF

10 V/m

10 V/m

d = 0.35 √P 80 MHz to 800 MHz

IEC 61000-4-3

80 MHz to 2.5 GHz

 

 

 

 

 

d = 0.70 √P 800 MHz to 2.5 GHz

 

 

 

where P is the maximum output power rating of

 

 

 

the transmitter in watts (W) according to the

 

 

 

transmitter manufacturer and d is the

 

 

 

recommended separation distance in meters (m).

 

 

 

Field strengths from fixed RF transmitters, as

 

 

 

determined by an electromagnetic site survey,a

 

 

 

should be less than the compliance level in each

 

 

 

frequency range.b

 

 

 

Interference may occur in the vicinity of

 

 

 

equipment marked with the following symbol:

 

 

 

 

NOTE 1: At 80 MHz and 800MHz, the higher frequency range applies.

NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

aField strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the AutoSet CS2 is used exceeds the applicable RF compliance level above, the AutoSet CS2 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the AutoSet CS2.

bOver the frequency range 150 kHz to 80 MHz, field strengths should be less than 10 V/m.

ENGLISH

TECHNICAL SPECIFICATIONS

49

Image 53
Contents AutoSet CS EUR AutoSet CS Page Autoset CS Page Table of Contents Cleaning and Maintenance Autoset CS2 IntroductionUSER/OWNER Responsibility Medical InformationPage Quick Setup Guide Page Autoset CS2 Components Autoset CS2 SystemConnect this end Assembling the Autoset CS2 System Connect the power cordConnect air tubing Attach the mask to the air tubing HumidifiersConnecting a Humidifier Humidaire Perform the Air Circuit Learn function see ANTI-BACTERIAL Filter ReslinkInserting anti-bacterial filters Using DC Power to RUN the Autoset CS2Oxygen tube attached to Mirage FFMS2 and Ultra Mirage masks Using Supplemental OxygenPage Standby Mode Using the Autoset CS2Starting Treatment Stopping TreatmentLCD Screen Control Panel FunctionsSTART/STOP KEY UP/DOWN KEYAlarm Leds and Alarm Mute Adjusting SettingsLeft KEY Green Right KEY REDExample You wish to change the sound level for the alarmsNavigating the Patient menu MenusLearn Circuit MaskSound Level SmartstopLeak Alert Average Pressure Mask FITUsage Smart DataApnea Treatment ScreensPage Triggered by AlarmsIf a LOW Pressure Alarm Sounds If a High Pressure Alarm Sounds If a Power Fail Alarm SoundsIf a High Leak Alarm Sounds Will Clear WhenIf a Flow Blocked Alarm Sounds If AN Insufficient Pressure Support Alarm SoundsPage Weekly Cleaning and MaintenanceDaily AIR Filter PeriodicallyFitting the Filter ServicingPage Problem Possible cause Solution TroubleshootingPage Glossary Page Technical Specifications Leak exceeds 30 L/min for more than 20 seconds Max Pressure Environmental information English Next Recommended separation distance Separation distance according to frequency of transmitter Product Warranty Period Limited WarrantyPage Index Page Manuel Utilisateur Page Sommaire Nettoyage ET Entretien Informations Medicales Responsabilite DE L’UTILISATEUR/DU ProprietaireAvertissements PrecautionsGuide D’INSTALLATION Rapide Page Composants DE L’AUTOSET CS2 Autoset CS2Raccordez cette extrémité Montage DE L’AUTOSET CS2 AvertissementRaccordez le circuit respiratoire Montage de l’AutoSet CS2 HumidificateursVoir « Début du traitement » De l’AutoSet CS2 Avertissement Filtre Antibacterien Mise en place des filtres antibactériens Utilisation D’UNE Alimentation CC Avec L’AUTOSET CS2Utilisation D’OXYGENE Supplementaire AvertissementsPage Utilisation DE L’AUTOSET CS2 Mode D’ATTENTEDebut DU Traitement Arret DU TraitementFonctions DU Panneau DE Controle Touche DE Deplacement Vers LE HAUT/BASEcran LCD Touche MARCHE/ARRETModification DES Reglages Temoins D’ALARME ET Desactivation DE L’ALARMETouche DE Gauche Verte Touche DE Droite RougeExemple Vous souhaitez modifier le niveau du son pour les alarmesNavigation dans le menu Patient IDENT. Circuit MasqueAI Faible Alarme FuiteUtilisation Ajustement DU MasquePression Moyenne Langue Ecrans DE TraitementRETRO-ECL Remarquecibl nest pas un paramètre utilisé en mode Cpap Declenchee Lorsque LES AlarmesSI UNE Alarme DE Panne DE Courant SE Declenche SI UNE Alarme DE Pression Basse SE DeclencheSI UNE Alarme DE Pression Elevee SE Declenche ’ARRETE LorsqueSI L’ALARME DE Debit Bloque SE Declenche SI UNE Alarme DE Fuite Importante SE DeclencheSI L’ALARME D’AIDE Inspiratoire Insuffisante SE Declenche Page Hebdomadaire Nettoyage ET EntretienQuotidien Démontage du circuit respiratoire pour le nettoyage PeriodiqueMise EN Place DU Filtre Filtre a AIREntretien Strategie DE Depannage Problème Cause possible SolutionPage Glossaire Page Caracteristiques Cm H2O, si cette valeur est inférieure Pression Max Informations concernant l’environnement 101 102 103 104 Produit Durée de la Garantie Garantie Limitee106 Index 108

AutoSet CS 2 specifications

ResMed AutoSet CS 2 is a state-of-the-art device designed for individuals suffering from complex sleep apnea and central sleep apnea. This advanced treatment solution leverages innovation and cutting-edge technology to provide optimal comfort and effective therapy during sleep, ultimately helping users achieve a better quality of life.

One of the standout features of the AutoSet CS 2 is its sophisticated auto-adjusting pressure capabilities. The device automatically detects and responds to the patient's breathing patterns throughout the night, adjusting the pressure levels in real time to ensure that airway obstructions are effectively managed. This technology helps prevent both hypopneas and apneas, providing a seamless therapy experience.

The device is equipped with ResMed's proprietary Easy-Breathe technology, which allows for smooth pressure changes that mimic the user's natural breathing cycle. This feature enhances user comfort, making it easier for individuals to adapt to CPAP therapy and continue using the device consistently over time.

Another remarkable characteristic of the AutoSet CS 2 is its integrated wireless connectivity. This connectivity facilitates remote monitoring and data sharing with healthcare professionals, enabling more effective management of treatment progress. By analyzing sleep data, providers can make informed adjustments to therapy, ensuring that the patient receives the best possible care.

The AutoSet CS 2 also includes a user-friendly interface with a high-resolution color display, making it easy for users to navigate menus and access vital information about their sleep patterns and therapy effectiveness. With its compact design, the device is portable and can easily be used at home or while traveling.

In terms of comfort, the AutoSet CS 2 features a quiet operation, enabling a peaceful sleep environment. It is compatible with various masks, providing flexibility for users to find the best fit for their personal comfort preferences.

Overall, the ResMed AutoSet CS 2 is a leading choice for individuals with complex sleep apnea. With its combination of advanced features, user-centric design, and state-of-the-art technology, it empowers users to take control of their sleep and improve their overall health and well-being.