ResMed AutoSet CS 2 user manual

Page 10

!WARNINGS

The AUTOSET CS2 is NOT a life support ventilator.

The entire manual should be read before using the AUTOSET CS2.

Advice contained in this manual should not supersede instructions given by the prescribing physician.

The AUTOSET CS2 should be used with masks and accessories recommended by ResMed or the prescribing physician. Use of incorrect masks and accessories may adversely affect the function of the AUTOSET CS2.

The AUTOSET CS2 is designed for use with masks that allow exhaled gases to be flushed out through vent holes. Exhaled gases will be rebreathed if the mask is worn with the machine turned off, or the vent holes are occluded. If this occurs over prolonged periods, suffocation may occur.

In the event of power failure or machine malfunction, remove the mask.

The air flow for breathing produced by this device can be as much as 6oC (11oF)

higher than the temperature of the room. Caution should be exercised if the room temperature is warmer than 32oC (90oF).

The AUTOSET CS2 can be set to deliver pressures up to 20 cmH2O. In the unlikely event of certain fault conditions, pressures of up to 40 cmH2O for up to 0.7 seconds are possible.

The AUTOSET CS2 is not suitable for use in the vicinity of flammable anaesthetics.

If oxygen is used with the AUTOSET CS2, the oxygen flow should be stopped when the device is not operating. If oxygen flow continues when the device is not operating, oxygen may accumulate within the device and create a risk of fire.

Do not use the AUTOSET CS2 if there are obvious external defects or unexplained changes in performance.

Do not open the AUTOSET CS2 case. There are no user serviceable parts inside. Repairs and internal servicing should only be performed by an authorised service agent.

!CAUTIONS

You should report unusual chest pain, severe headache or increased breathlessness to your physician. An acute upper respiratory tract infection may require temporary discontinuation of treatment.

The following side effects may arise during a course of therapy with the AUTOSET CS2:

drying of the nose, mouth or throat

bloating

ear or sinus discomfort

eye irritation

skin rashes

chest discomfort.

6

Image 10
Contents AutoSet CS EUR AutoSet CS Page Autoset CS Page Table of Contents Cleaning and Maintenance USER/OWNER Responsibility IntroductionAutoset CS2 Medical InformationPage Quick Setup Guide Page Autoset CS2 System Autoset CS2 ComponentsConnect this end Connect the power cord Assembling the Autoset CS2 SystemConnect air tubing Humidifiers Attach the mask to the air tubingConnecting a Humidifier Humidaire Perform the Air Circuit Learn function see Reslink ANTI-BACTERIAL FilterUsing DC Power to RUN the Autoset CS2 Inserting anti-bacterial filtersUsing Supplemental Oxygen Oxygen tube attached to Mirage FFMS2 and Ultra Mirage masksPage Starting Treatment Using the Autoset CS2Standby Mode Stopping TreatmentSTART/STOP KEY Control Panel FunctionsLCD Screen UP/DOWN KEYLeft KEY Green Adjusting SettingsAlarm Leds and Alarm Mute Right KEY REDYou wish to change the sound level for the alarms ExampleMenus Navigating the Patient menuMask Learn CircuitLeak Alert SmartstopSound Level Usage Mask FITAverage Pressure Smart DataTreatment Screens ApneaPage If a LOW Pressure Alarm Sounds AlarmsTriggered by If a High Leak Alarm Sounds If a Power Fail Alarm SoundsIf a High Pressure Alarm Sounds Will Clear WhenIf AN Insufficient Pressure Support Alarm Sounds If a Flow Blocked Alarm SoundsPage Daily Cleaning and MaintenanceWeekly Periodically AIR FilterServicing Fitting the FilterPage Troubleshooting Problem Possible cause SolutionPage Glossary Page Technical Specifications Leak exceeds 30 L/min for more than 20 seconds Max Pressure Environmental information English Next Recommended separation distance Separation distance according to frequency of transmitter Limited Warranty Product Warranty PeriodPage Index Page Manuel Utilisateur Page Sommaire Nettoyage ET Entretien Responsabilite DE L’UTILISATEUR/DU Proprietaire Informations MedicalesPrecautions AvertissementsGuide D’INSTALLATION Rapide Page Autoset CS2 Composants DE L’AUTOSET CS2Raccordez cette extrémité Avertissement Montage DE L’AUTOSET CS2Raccordez le circuit respiratoire Humidificateurs Montage de l’AutoSet CS2Voir « Début du traitement » De l’AutoSet CS2 Avertissement Filtre Antibacterien Utilisation D’UNE Alimentation CC Avec L’AUTOSET CS2 Mise en place des filtres antibactériensAvertissements Utilisation D’OXYGENE SupplementairePage Debut DU Traitement Mode D’ATTENTEUtilisation DE L’AUTOSET CS2 Arret DU TraitementEcran LCD Touche DE Deplacement Vers LE HAUT/BASFonctions DU Panneau DE Controle Touche MARCHE/ARRETTouche DE Gauche Verte Temoins D’ALARME ET Desactivation DE L’ALARMEModification DES Reglages Touche DE Droite RougeVous souhaitez modifier le niveau du son pour les alarmes ExempleNavigation dans le menu Patient Masque IDENT. CircuitAlarme Fuite AI FaiblePression Moyenne Ajustement DU MasqueUtilisation RETRO-ECL Ecrans DE TraitementLangue Remarquecibl nest pas un paramètre utilisé en mode Cpap LES Alarmes Declenchee LorsqueSI UNE Alarme DE Pression Elevee SE Declenche SI UNE Alarme DE Pression Basse SE DeclencheSI UNE Alarme DE Panne DE Courant SE Declenche ’ARRETE LorsqueSI L’ALARME D’AIDE Inspiratoire Insuffisante SE Declenche SI UNE Alarme DE Fuite Importante SE DeclencheSI L’ALARME DE Debit Bloque SE Declenche Page Quotidien Nettoyage ET EntretienHebdomadaire Periodique Démontage du circuit respiratoire pour le nettoyageFiltre a AIR Mise EN Place DU FiltreEntretien Problème Cause possible Solution Strategie DE DepannagePage Glossaire Page Caracteristiques Cm H2O, si cette valeur est inférieure Pression Max Informations concernant l’environnement 101 102 103 104 Garantie Limitee Produit Durée de la Garantie106 Index 108

AutoSet CS 2 specifications

ResMed AutoSet CS 2 is a state-of-the-art device designed for individuals suffering from complex sleep apnea and central sleep apnea. This advanced treatment solution leverages innovation and cutting-edge technology to provide optimal comfort and effective therapy during sleep, ultimately helping users achieve a better quality of life.

One of the standout features of the AutoSet CS 2 is its sophisticated auto-adjusting pressure capabilities. The device automatically detects and responds to the patient's breathing patterns throughout the night, adjusting the pressure levels in real time to ensure that airway obstructions are effectively managed. This technology helps prevent both hypopneas and apneas, providing a seamless therapy experience.

The device is equipped with ResMed's proprietary Easy-Breathe technology, which allows for smooth pressure changes that mimic the user's natural breathing cycle. This feature enhances user comfort, making it easier for individuals to adapt to CPAP therapy and continue using the device consistently over time.

Another remarkable characteristic of the AutoSet CS 2 is its integrated wireless connectivity. This connectivity facilitates remote monitoring and data sharing with healthcare professionals, enabling more effective management of treatment progress. By analyzing sleep data, providers can make informed adjustments to therapy, ensuring that the patient receives the best possible care.

The AutoSet CS 2 also includes a user-friendly interface with a high-resolution color display, making it easy for users to navigate menus and access vital information about their sleep patterns and therapy effectiveness. With its compact design, the device is portable and can easily be used at home or while traveling.

In terms of comfort, the AutoSet CS 2 features a quiet operation, enabling a peaceful sleep environment. It is compatible with various masks, providing flexibility for users to find the best fit for their personal comfort preferences.

Overall, the ResMed AutoSet CS 2 is a leading choice for individuals with complex sleep apnea. With its combination of advanced features, user-centric design, and state-of-the-art technology, it empowers users to take control of their sleep and improve their overall health and well-being.