ResMed AutoSet CS 2 user manual Reslink, ANTI-BACTERIAL Filter

Page 21

CAUTION

! Be very careful not to allow water to enter the AUTOSET CS2 as this could affect therapy and/or damage the device.

Do not tip the HUMIDAIRE while it is connected to the AUTOSET CS2. If water enters the AUTOSET CS2 device, turn off the main power switch at the back of the unit and unplug it from the power outlet. Return the unit to your equipment supplier for checking.

Set up the HUMIDAIRE and the AUTOSET CS2 unit so that the tubing to the mask runs higher than the machines. This will prevent condensation build-up.

If condensation appears in the mask, turn the humidifier settings down.

RESLINK

The RESLINKis a device that records data onto a SmartMedia™ card during your therapy. The card can be returned to your clinician so that they can observe your progress and adjust flow generator parameters if necessary. The RESLINK connects to the back of AUTOSET CS2 as shown. For full details on using the RESLINK, please refer to the ResLink User’s Manual.

ANTI-BACTERIAL FILTER

Your clinician may recommend that you use an anti-bacterial filter. A filter should be placed in the air tubing between the mask and the flow generator. If using a humidifier, place the filter between it and the flow generator (see Figure 10 below).

Typically, the filter should be replaced daily. Check the filter instructions for full details.

Whenever a filter is added, removed or replaced you must run the Air Circuit Learn function (see “Learn Circuit” on page 26).

NOTE Only hydrophobic anti-bacterial filters should be used with a HUMIDAIRE 2i or HUMIDAIRE 2iC.

ENGLISH

THE AUTOSET CS2 SYSTEM

17

Image 21
Contents AutoSet CS EUR AutoSet CS Page Autoset CS Page Table of Contents Cleaning and Maintenance Autoset CS2 IntroductionUSER/OWNER Responsibility Medical InformationPage Quick Setup Guide Page Autoset CS2 Components Autoset CS2 SystemConnect this end Assembling the Autoset CS2 System Connect the power cordConnect air tubing Attach the mask to the air tubing HumidifiersConnecting a Humidifier Humidaire Perform the Air Circuit Learn function see ANTI-BACTERIAL Filter ReslinkInserting anti-bacterial filters Using DC Power to RUN the Autoset CS2Oxygen tube attached to Mirage FFMS2 and Ultra Mirage masks Using Supplemental OxygenPage Standby Mode Using the Autoset CS2Starting Treatment Stopping TreatmentLCD Screen Control Panel FunctionsSTART/STOP KEY UP/DOWN KEYAlarm Leds and Alarm Mute Adjusting SettingsLeft KEY Green Right KEY REDExample You wish to change the sound level for the alarmsNavigating the Patient menu MenusLearn Circuit MaskSmartstop Leak AlertSound Level Average Pressure Mask FITUsage Smart DataApnea Treatment ScreensPage Alarms If a LOW Pressure Alarm SoundsTriggered by If a High Pressure Alarm Sounds If a Power Fail Alarm SoundsIf a High Leak Alarm Sounds Will Clear WhenIf a Flow Blocked Alarm Sounds If AN Insufficient Pressure Support Alarm SoundsPage Cleaning and Maintenance DailyWeekly AIR Filter PeriodicallyFitting the Filter ServicingPage Problem Possible cause Solution TroubleshootingPage Glossary Page Technical Specifications Leak exceeds 30 L/min for more than 20 seconds Max Pressure Environmental information English Next Recommended separation distance Separation distance according to frequency of transmitter Product Warranty Period Limited WarrantyPage Index Page Manuel Utilisateur Page Sommaire Nettoyage ET Entretien Informations Medicales Responsabilite DE L’UTILISATEUR/DU ProprietaireAvertissements PrecautionsGuide D’INSTALLATION Rapide Page Composants DE L’AUTOSET CS2 Autoset CS2Raccordez cette extrémité Montage DE L’AUTOSET CS2 AvertissementRaccordez le circuit respiratoire Montage de l’AutoSet CS2 HumidificateursVoir « Début du traitement » De l’AutoSet CS2 Avertissement Filtre Antibacterien Mise en place des filtres antibactériens Utilisation D’UNE Alimentation CC Avec L’AUTOSET CS2Utilisation D’OXYGENE Supplementaire AvertissementsPage Utilisation DE L’AUTOSET CS2 Mode D’ATTENTEDebut DU Traitement Arret DU TraitementFonctions DU Panneau DE Controle Touche DE Deplacement Vers LE HAUT/BASEcran LCD Touche MARCHE/ARRETModification DES Reglages Temoins D’ALARME ET Desactivation DE L’ALARMETouche DE Gauche Verte Touche DE Droite RougeExemple Vous souhaitez modifier le niveau du son pour les alarmesNavigation dans le menu Patient IDENT. Circuit MasqueAI Faible Alarme FuiteAjustement DU Masque Pression MoyenneUtilisation Ecrans DE Traitement RETRO-ECLLangue Remarquecibl nest pas un paramètre utilisé en mode Cpap Declenchee Lorsque LES AlarmesSI UNE Alarme DE Panne DE Courant SE Declenche SI UNE Alarme DE Pression Basse SE DeclencheSI UNE Alarme DE Pression Elevee SE Declenche ’ARRETE LorsqueSI UNE Alarme DE Fuite Importante SE Declenche SI L’ALARME D’AIDE Inspiratoire Insuffisante SE DeclencheSI L’ALARME DE Debit Bloque SE Declenche Page Nettoyage ET Entretien QuotidienHebdomadaire Démontage du circuit respiratoire pour le nettoyage PeriodiqueMise EN Place DU Filtre Filtre a AIREntretien Strategie DE Depannage Problème Cause possible SolutionPage Glossaire Page Caracteristiques Cm H2O, si cette valeur est inférieure Pression Max Informations concernant l’environnement 101 102 103 104 Produit Durée de la Garantie Garantie Limitee106 Index 108

AutoSet CS 2 specifications

ResMed AutoSet CS 2 is a state-of-the-art device designed for individuals suffering from complex sleep apnea and central sleep apnea. This advanced treatment solution leverages innovation and cutting-edge technology to provide optimal comfort and effective therapy during sleep, ultimately helping users achieve a better quality of life.

One of the standout features of the AutoSet CS 2 is its sophisticated auto-adjusting pressure capabilities. The device automatically detects and responds to the patient's breathing patterns throughout the night, adjusting the pressure levels in real time to ensure that airway obstructions are effectively managed. This technology helps prevent both hypopneas and apneas, providing a seamless therapy experience.

The device is equipped with ResMed's proprietary Easy-Breathe technology, which allows for smooth pressure changes that mimic the user's natural breathing cycle. This feature enhances user comfort, making it easier for individuals to adapt to CPAP therapy and continue using the device consistently over time.

Another remarkable characteristic of the AutoSet CS 2 is its integrated wireless connectivity. This connectivity facilitates remote monitoring and data sharing with healthcare professionals, enabling more effective management of treatment progress. By analyzing sleep data, providers can make informed adjustments to therapy, ensuring that the patient receives the best possible care.

The AutoSet CS 2 also includes a user-friendly interface with a high-resolution color display, making it easy for users to navigate menus and access vital information about their sleep patterns and therapy effectiveness. With its compact design, the device is portable and can easily be used at home or while traveling.

In terms of comfort, the AutoSet CS 2 features a quiet operation, enabling a peaceful sleep environment. It is compatible with various masks, providing flexibility for users to find the best fit for their personal comfort preferences.

Overall, the ResMed AutoSet CS 2 is a leading choice for individuals with complex sleep apnea. With its combination of advanced features, user-centric design, and state-of-the-art technology, it empowers users to take control of their sleep and improve their overall health and well-being.