Dynacord Xa 4000 owner manual Specifications, Sub Top

Page 42

SPECIFICATIONS

Amplifier at rated conditions, both channels driven, 8loads, unless otherwise specified.

Xa 4000

 

 

SUB

 

 

 

 

TOP

 

 

 

 

 

 

 

 

 

 

 

 

Load Impedance

2

 

4

8

 

2

 

4

 

8

 

 

 

 

 

 

 

 

 

 

 

Maximum Midband Output Power

1800W

 

1100W

600W

 

1600W

 

900W

 

500W

THD = 1%, 80Hz SUB, 1kHz TOP, Single Channel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated Output Power

----

 

1000W

500W

 

---

 

800W

 

400W

THD < 0.1%, 20Hz-140Hz SUB, 140Hz-20kHz TOP

 

 

 

 

 

 

 

 

 

 

Single Channel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum RMS Voltage Swing

 

 

 

 

78V

 

 

 

THD = 1%, 80Hz SUB, 1kHz TOP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Bandwith

 

 

 

10Hz … 50kHz

 

 

 

THD = 1%, ref. 1kHz, half power @ 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage Gain

 

 

 

37.3dB

 

 

 

ref.1kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Sensitivity

 

 

 

0dBu (0.775V rms)

 

 

 

at rated output power, 1kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THD at rated output power,

 

 

 

< 0.05%

 

 

 

 

MBW = 80kHz, 1kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Input Level

 

 

 

+22dBu (9.76V rms)

 

 

 

 

 

 

 

 

 

 

 

Input Impedance

 

 

 

20k

 

 

 

active balanced

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Damping Factor

 

 

 

> 300

 

 

 

 

1kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slew Rate

 

 

 

30V/µs

 

 

 

 

 

 

 

 

 

 

 

Signal to Noise Ratio Amplifier

 

 

 

102dB

 

 

 

A-weighted

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Stage Topology

 

 

 

Class H

 

 

 

 

 

 

Power Requirements

240, 230, 220, 120V or 100V;

50Hz ... 60Hz ( factory configured )

 

 

 

 

 

 

 

 

Power Consumption

 

 

 

850W

 

 

 

at 1/8 maximum output power @ 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protection

 

 

Audio limiters, High temperature, DC, HF, Back-EMF,

 

 

 

Peak current limiters, Inrush current limiters, Turn-on delay

 

 

 

 

 

 

 

 

 

Cooling

 

 

 

Front-to-rear, 3-stage-fans

 

 

 

 

 

 

 

 

 

 

 

 

Ambient Temperature Limits

 

 

+5°C … +40°C

 

( 40°F … 105°F)

 

 

 

 

 

 

 

 

 

 

 

 

Safety Class

 

 

 

 

I

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

 

 

483 x 88.1 x 384

 

 

 

(W x H x D), mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

 

 

 

8.25kg

 

 

 

 

 

 

 

(18.2lbs)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional:

 

 

 

 

 

 

 

 

 

 

Rear-rackmount 15,5”

 

 

 

112930 (RMS15-CL)

 

 

 

Rear-rackmount 18”

 

 

 

112933 (RMS18-CL)

 

 

 

Notes:

-Depending on the ambient temperature, the unit might not operate continuously at 2load.

-Due to mains voltage in Japan (100V/50Hz) the values for the maximum output power can be decreased up to 15% (only 100V version)!

42

Image 42
Contents OWNER‘S Manual Bedienungsanleitung Mode D‘EMPLOI Contents Table DES MatièresSafety Component Must be Replaced by Original Part Are placed on the equipmentDescription Remarques Concernant L’INSTALLATION Déballage ET GarantieFront Panel Rear Panel InputNF-CONNECTION Cords Power Amplifier Output Connectors GROUND-LIFT SwitchMains Input Mains Operation & Resulting Temperatures Mains Operation & Resulting Power AMP TemperaturesAdjustments with Real Time Analyser and Equalizer EqualiserGeneral Installation Notes General Installation NotesExamples for Active 2-WAY Applications Examples for Active 2-WAY Applications Page Bedienungsanleitung Einstellhinweise Aufbauhinweise Achtung Beschreibung Installationshinweise Auspacken & GarantieFrontseite Rückseite InputNF-VERBINDUNGSKABEL Endstufenausgangsbuchsen GROUND-LIFT SchalterNetzeingang Netzbetrieb & Wärmeentwicklung in DER Endstufe Netzbetrieb & Wärmeentwicklung in DER EndstufeEqualiser EinstellhinweiseEinstellhinweise Einmessen MIT Real Time Analyser UND EqualiserAufbauhinweise Aufbauhinweise FÜR Aktiv 2-WEG AnlagenBeispiele FÜR Aktiv 2-WEG Anlagen Beispiele FÜR Aktiv 2-WEG Anlagen Page Mode D‘EMPLOI Table DES Matières Instructions DE Sécurité Importantes Description Déballage ET Garantie Face Avant Arrière Cordons DE Connexion AudioBrochage D‘UN Connecteur DE Type XLR Connecteurs DE Sortie DE L‘AMPLIFICATEUR DE Puissance Commutateur GROUND-LIFTEntrée Secteur Fonctionnement SUR LE Secteur ET Températures Fonctionnement SUR LE Secteur ET Températures RésultantesRemarques SUR LES Réglages Remarques SUR LES RéglagesÉgaliseurs Remarques Générales SUR L‘INSTALLATION Remarques Générales SUR L‘INSTALLATIONExemples D‘APPLICATIONS Actives À 2 Voies Exemples D‘APPLICATIONS Actives À 2 Voies Specifications SUB TOPBlock Diagram Dimensions Page Page Page Bosch Communications Systems