Chapter 3: Testing Performance
To test the
To test the multiple-clock state acquisition
Testing the
•Minimum
•Maximum state acquisition speed.
•Setup/Hold time for
This test checks two combinations of data using multiple clocks at two selected setup/hold times.
Equipment Required
Equipment | Critical Specifications | Recommended Model/Part |
|
|
|
Pulse Generator | 200 MHz 3.0 ns pulse width, | 8133A option 003 |
| < 600 ps rise time |
|
Digitizing Oscilloscope | ≥ 6 GHz bandwidth, < 58 ps rise time | 54750A w/ 54751A |
Adapter | ||
SMA Coax Cable (Qty 3) | 18 GHz bandwidth | |
Coupler | BNC(m)(m) | |
BNC Test Connector, |
|
|
6x2 (Qty 4) |
|
|
|
|
|
Set up the equipment
1If you have not already done so, do the following procedures:
“To set up the test equipment and the logic analyzer” on page 23. “To set up the logic analyzer for the state mode tests” on page 33.
2Increase the pulse generator channel 2 width to 3.000 ns.
48