Chapter 3: Testing Performance
To test the
Connect the 1682/83/92/93A,AD Logic Analyzer to the Pulse Generator
Testing | Connect to 8133A | Connect to 8133A | Connect to 8133A |
Combination | Channel 2 Output | Channel 2 Output | Channel 1 Output |
1 | Pod 1, channel 3 |
| Pod 2, channel 3 |
| Pod 3, channel 3 |
| Pod 4, channel 3 |
*1682A, AD or 1692A, AD only.
Pod 1, channel 11 Pod 2, channel 11 Pod 3, channel 11 * Pod 4, channel 11 *
Clock/data channel for Pod 1, 2, 3, and 4 (Clk 1, Clk 2, Clk 3, Clk 4)
3Activate the data channels that are connected according to one of the previous tables:
a Click the
Bus/Signal Setup icon. The Analyzer Setup dialog opens.
b Under the Buses/Signals tab, click Delete All at the bottom of the dialog.
c Using the mouse, activate the data channels being tested. Assign channels to bus/signal name My Bus 1.
d Click OK to close the Analyzer Setup dialog.
50