NEPTUNE 5 SB FA
8 | Troubleshooting |
|
| ||
8.1 Indications on Display |
|
| |||
|
|
|
|
| |
Indication |
| Cause |
| Remedy | |
on Display |
|
| |||
|
|
|
| ||
|
|
|
|
|
|
FLF |
| > | Flow sensor fault |
| Contact Nilfi |
|
| Cold water operation possible | |||
|
|
|
| ||
|
|
|
|
|
|
FLO |
| > | Water supply turned off or inadequate supply | • | Required volume fl ow and pressure see |
|
| ||||
|
|
| to machine |
| chapter 9.4 Technical Data |
|
| > | Detergent tank empty | • | Fill detergent tank or set detergent me- |
|
|
|
|
| tering to „OFF“ |
|
| > | Pressure regulation on the safety control | • | Turn the twist grip on safety control block |
|
|
| block set to low water volume |
| to higher water pressure/volume |
|
| > | Machine scaled |
| Contact Nilfi |
|
|
|
|
|
|
Fue |
| > | Fuel shortage | • | Fill fuel tank |
|
|
| Cold water operation possible | ||
|
|
|
| ||
|
|
|
|
|
|
Hop |
| > | Motor overheated | • | Turn main switch in position „OFF“, let |
|
|
|
| machine cool down | |
|
|
|
| • | Remove extension cord, if being used. |
|
|
|
| • | Possible phase failure; have electrical |
|
|
|
|
| connections checked |
|
|
|
|
|
|
HOS |
| > | Machine overheated |
| Contact Nilfi |
|
|
|
|
|
|
|
| > | Leakage or inadmissible operating condition | • | After three times of |
|
|
| by |
| the machine switches off. To reset: Turn |
|
|
|
|
| main switch to position “OFF“, then start |
LEA |
|
|
|
| again. Keep trigger squeezed for longer |
|
|
|
| than 3 seconds. If a leak occurs in the | |
|
|
|
|
| hose and gun and causes the machine |
|
|
|
|
| to start and stop briefl y 3 times, then the |
|
|
|
|
| machine will switch off. |
|
| > | Spray gun leaking | • | Repair Spray gun |
|
| > | High pressure hose, coupling or line system | • | Replace |
|
|
| leaking |
| screw fi ttings |
|
| > | Detergent tank empty | • | Fill detergent tank or set detergent me- |
|
|
|
|
| tering to „OFF“ |
|
| > | Water inlet fi lter dirty | • | Clean fi lter (see chapter 7.2.1) |
|
| > | • | Repair leaks | |
|
|
|
|
|
|
LHE |
| > | Flame sensor sooted | • | Clean flame sensor (see chapter |
|
|
|
| 7.2.6). | |
|
| > Ignition or fuel system failure |
| Contact Nilfi | |
|
|
|
|
| Cold water operation possible |
|
|
|
|
|
|
LHL |
| > | Burner failure |
| Contact Nilfi |
|
| Cold water operation possible | |||
|
|
|
| ||
|
|
|
|
|
|
POL |
| > | Pump oil low | • | Fill to proper level (see chapter 7.2.3) |
|
|
| |||
SEC |
| > | Temperature sensor damaged |
| Contact Nilfi |
|
| Cold water operation possible | |||
|
|
|
| ||
|
|
|
|
|
|
SEO |
| > | Temperature sensor damaged |
| Contact |
|
| Cold water operation possible | |||
|
|
|
| ||
|
|
|
|
|
|
UPC |
| > | Microprocessor failure |
| Contact |
|
|
|
|
|
|
1) Options / model variants | 19 |