Nilfisk-ALTO 5 SB FA Install Crank handle for high pressure hose reel/cord reel, Antiscale

Page 8

NEPTUNE 5 SB FA

3.3Install Crank handle for high pressure hose reel/cord reel

1.Pull cap of crank in arrow direction.

2.Align tabs on crank with slot in axle.

3.Put crank on axle of high pres- sure hose reel/cord reel.

4.Fix crank by pushing the cap.

3.4Fill up detergent tanks

3.5Fill up tank for Nilfisk- ALTO AntiStone (Anti- Scale)

A

B

1.Fill up detergent tanks (A) and

(B) with prediluted detergent. Capacity see chapter 9.4 Technical Data

1.Fill up Nilfisk-ALTO Anti-Stone (Anti-Scale)/water softener reservoir with the sample bottle provided. Nilfi sk-ALTO AntiStone (Anti-Scale) pre- vents any deposits of scale

and acts at the same time as a corrosion inhibitor.

For compatibility reasons, use only the tested Nilfisk-ALTO AntiStone (Anti-Scale) which is available as a six-pack of 1 liter bottles by ordering part number 8466.

3.6Antiscale

The Nilfisk Alto Antiscale dosing

Use the schematic to find

the

system is set by the factory.

right dosage of No Scale/anti

To adjust the water hardness we

stone and water, and add

the

recommend that the inlet water

mixture to the antiscale tank.

is tested accordingly.

 

 

Machine flow L/h

Pump size ml/h

˚dH

˚f

 

˚e

Dosage

 

 

 

 

 

 

 

900

35

0-12

0-21,5

0

- 15

1:1 = 17ml/h

 

 

 

 

 

 

900

35

12-30

21,5 - 53,7

15 - 37,5

Pure = 35ml/h

 

 

 

 

 

 

 

1000

35

0-12

0-21,5

0

- 15

1:1 = 17ml/h

 

 

 

 

 

 

1000

35

12-30

21,5 - 53,7

15 - 37,5

Pure = 35ml/h

 

 

 

 

 

 

 

6

1) Options / model variants

Image 8
Contents Neptune 5 SB FA Neptune 5 SB FA Contents Important safety instructions Symbols used to mark instructionsFor your own safety GeneralOperation LiquidWater connection Testing DescriptionBypass valve PurposeSet the brake Before starting the cleanerTransport and assembly Machine flow L/h Pump size ml/h ˚dH Dosage Install Crank handle for high pressure hose reel/cord reelAntiscale Connecting the water supply Fill up fuel tankControl / Operation Mode Setting Self-service modeDaily tasks Switching off the cleaner Options / model variants Options / model variants Applications and methods Vehicle Task Accessories Method Buildings and Equipment Task Accessories Method After using the cleaner Storing the cleanerLines Below 0C 32FMaintenance Checking the pump oil quality Changing the pump oilEmptying the fuel oil TankTroubleshooting Indications on DisplayOther Faults Indication lights on control panelUS only GuaranteeFurther information EU Declaration of Conformity EU Declaration of ConformityInhalt Wichtige Sicherheitshinweise Kennzeichnung vonWarnung AllgemeinesBetrieb Schutzkleidung und Schutz- brille tragenWasseranschluss Beschreibung ElektrikWartung und Reparatur PrüfungVor der Inbetriebnahme BedienelementeTransport/Aufstellung Bremse einlegenKurbel für Schlauchtrommel und Kabeltrommel montieren Reinigungsmitteltanks füllenVorratsbehälter für Nilfisk-Alto AntiStone füllen Durchfluss l/h Pumpengröße ml/h ˚dH DosierungBrennstofftank füllen Wasserschlauch anschließenBedienung / Betrieb Elektrischer Anschluss AchtungFrostschutzmittel AuffangenSchalterstellung Oder Hinweis SB-Betrieb/manuellen Betrieb einstellenBetriebsart SB-Betrieb Tägliche KontrollenSpritzpistole verriegeln Dampfbetrieb über 100C Verwendung von ReinigungsmittelnAnwendungsgebiete und Arbeitsmethoden Temperatur MechanischeEinwirkung Und hoher DruckFahrzeuge Anwendung Zubehör Methode OberflächenBau und Industrie Anwendung Zubehör Methode Ober flächenNach der Arbeit StolpergefahrAufbewahrung Frostsichere LagerungWartung Wartungsplan Nach den ersten Alle 6 Monate Bei WöchentlichBetriebsstunden Bedarf Wartungsarbeiten 7.2.1 Wasserfilter reinigenPumpenölkontrolle PumpenölwechselBrennstofftank EntleerenBehebung von Störungen Anzeigen am DisplaySonstiges Garantie EG- Konformitätserklärung EG KonformitätserklärungTechnical Data NeptunePage Head Quarter