NEPTUNE 5 SB FA
3.3Install Crank handle for high pressure hose reel/cord reel
1.Pull cap of crank in arrow direction.
2.Align tabs on crank with slot in axle.
3.Put crank on axle of high pres- sure hose reel/cord reel.
4.Fix crank by pushing the cap.
3.4Fill up detergent tanks
3.5Fill up tank for Nilfisk- ALTO AntiStone (Anti- Scale)
A |
B |
1.Fill up detergent tanks (A) and
(B) with prediluted detergent. Capacity see chapter 9.4 Technical Data
1.Fill up
and acts at the same time as a corrosion inhibitor.
For compatibility reasons, use only the tested
3.6Antiscale
The Nilfisk Alto Antiscale dosing | Use the schematic to find | the |
system is set by the factory. | right dosage of No Scale/anti | |
To adjust the water hardness we | stone and water, and add | the |
recommend that the inlet water | mixture to the antiscale tank. | |
is tested accordingly. |
|
|
Machine flow L/h | Pump size ml/h | ˚dH | ˚f |
| ˚e | Dosage |
|
|
|
|
|
|
|
900 | 35 | 0 | - 15 | 1:1 = 17ml/h | ||
|
|
|
|
|
| |
900 | 35 | 21,5 - 53,7 | 15 - 37,5 | Pure = 35ml/h | ||
|
|
|
|
|
|
|
1000 | 35 | 0 | - 15 | 1:1 = 17ml/h | ||
|
|
|
|
|
| |
1000 | 35 | 21,5 - 53,7 | 15 - 37,5 | Pure = 35ml/h | ||
|
|
|
|
|
|
|