CAUTION!

High-pressure water jets can be dangerous if misused. The jet must not be directed at persons, animals, live electri- cal equipment or the cleaner itself.

Wear appropriate protective clothing and eye protection. Do not direct the jet towards yourself or towards other per- sons in order to clean clothes or footwear.

During operation of the cleaner, recoil forces are produced at the gunvalve and spray lance and, when the spray lance is held at an angle, a torque is also cre- ated. The gunvalve and spray lancemust therefore be held fi rmly in both hands.

Do not use the cleaner when other people without protec- tive clothing are in the working area.

Check that cleaning will not result in dangerous substances (e.g. asbestos, oil) being washed off the object to be cleaned and harming the environment.

Do not clean delicate parts made of rubber, fabric, etc. with the 0° jet. Keep some distance between high pressure nozzle and surface in order to prevent the surface from damage.

Do not use the high-pressure hose for lifting loads.

NOTE!

The maximum permissible work- ing pressure and temperature are printed on the high-pressure hose.

Do not use the cleaner if the power cord or high-pressure hose is damaged.

Ensure adequate air circulation. Do not cover the cleaner or oper- ate it in inadequately ventilated rooms!

Store the cleaner where it will not be exposed to frost or use antifreeze

liquid!

Never operate the cleaner with- out water. Even brief shortages of water result in severe damage to the pump seals.

Water connection

This high pressure washer/cleaner is only allowed to be connected with the

drinking water

mains, when an appropriate backflow preventer has been installed, Type BA according to EN 1717. If the back flow pre- venter hasn’t been supplied, one can be ordered from your dealer. The length of the hose between the backflow preventer and the high pressure washer must be at least 12 metres (min diameter 3/4 inch) to absorb possible pressure peaks. Op- eration by suction (for example from a rainwater vessel) is car- ried out without backflow pre- venter. Contact your dealer for suction set recommendations.

As soon as water has flown through the BA valve, this water is not considered to be drinking water any more.

Operation

Keep cabinet and service door closed during operation.

CAUTION!

Unsuitable extension cords can represent a source of danger. Always unwind cord from the reels completely to prevent the power cord over- heating.

Connectors and couplings of extension cords must be water- tight.

Extension cords are not recom- mended, however if necessaray refer to the following recommen- dations:

 

 

NEPTUNE 5 SB FA

 

 

 

 

Cord length

Cross section

 

m

 

 

 

up to16 A

up to 25 A

 

 

 

 

 

 

 

up to 20 m

ø1.5mm²

ø2.5mm²

 

(US: 30 ft)

14 gauge

12 gauge

 

(US: 50 ft)

12 gauge

10 gauge

 

(US: 75 ft)

10 gauge

not recom-

 

 

 

mended

 

20 to 50 m

ø2.5mm²

ø4.0mm²

 

 

 

 

 

Do not damage the power cord (e.g. by driving over it, pulling or crushing it).

Disconnect the power cord by grasping the plug only (do not pull or tug the power cord).

CAUTION!

Unsuitable fuels (e.g. gasoline) must not be used as they can explode and catch fire.

Use clean fuel only, free of mois- ture and contamination. Contact your dealer for fuel source and type recommendations.

If the machine is to be operated at fuel stations or in other potentially hazardous areas, the machine may only be employed outside the hazard areas defi ned in the German „Technical Guidelines for Infl ammable Fluids“ applica- ble at the point of use due to the potential explosion hazard posed by the burner.

If the machine is to be operated indoors, the local building regu- lations must be observed for the discharge of the exhaust fumes into the atmosphere. Ensure an adequate supply of fresh air.

If the machine is to be con- nected to a fl ue gas stack, then local building regulations must be observed. We will be glad to pro- vide tips for connection systems, on request.

CAUTION!

Beware of hot water and steam discharge up to 1500C when operating in steam stage.

CAUTION!

Do not touch or cover the exhaust. Risk of burns and fire.

1) Options / model variants

3

Image 5
Contents Neptune 5 SB FA Neptune 5 SB FA Contents Symbols used to mark instructions Important safety instructionsFor your own safety GeneralOperation LiquidWater connection Description TestingBypass valve PurposeSet the brake Before starting the cleanerTransport and assembly Machine flow L/h Pump size ml/h ˚dH Dosage Install Crank handle for high pressure hose reel/cord reelAntiscale Fill up fuel tank Connecting the water supplyControl / Operation Self-service mode Mode SettingDaily tasks Switching off the cleaner Options / model variants Options / model variants Applications and methods Vehicle Task Accessories Method Buildings and Equipment Task Accessories Method Storing the cleaner After using the cleanerLines Below 0C 32FMaintenance Changing the pump oil Checking the pump oil qualityEmptying the fuel oil TankIndications on Display TroubleshootingIndication lights on control panel Other FaultsUS only GuaranteeFurther information EU Declaration of Conformity EU Declaration of ConformityInhalt Kennzeichnung von Wichtige SicherheitshinweiseWarnung AllgemeinesBetrieb Schutzkleidung und Schutz- brille tragenWasseranschluss Elektrik BeschreibungWartung und Reparatur PrüfungBedienelemente Vor der InbetriebnahmeTransport/Aufstellung Bremse einlegenReinigungsmitteltanks füllen Kurbel für Schlauchtrommel und Kabeltrommel montierenVorratsbehälter für Nilfisk-Alto AntiStone füllen Durchfluss l/h Pumpengröße ml/h ˚dH DosierungWasserschlauch anschließen Brennstofftank füllenElektrischer Anschluss Achtung Bedienung / BetriebFrostschutzmittel AuffangenSchalterstellung Oder Hinweis SB-Betrieb/manuellen Betrieb einstellenBetriebsart Tägliche Kontrollen SB-BetriebSpritzpistole verriegeln Verwendung von Reinigungsmitteln Dampfbetrieb über 100CAnwendungsgebiete und Arbeitsmethoden Mechanische TemperaturEinwirkung Und hoher DruckOberflächen Fahrzeuge Anwendung Zubehör MethodeBau und Industrie Anwendung Zubehör Methode Ober flächenStolpergefahr Nach der ArbeitAufbewahrung Frostsichere LagerungWartungsplan Nach den ersten Alle 6 Monate Bei Wöchentlich WartungBetriebsstunden Bedarf Wartungsarbeiten 7.2.1 Wasserfilter reinigenPumpenölwechsel PumpenölkontrolleBrennstofftank EntleerenAnzeigen am Display Behebung von StörungenSonstiges EG Konformitätserklärung Garantie EG- KonformitätserklärungNeptune Technical DataPage Head Quarter