FUNCTION TESTS
1Select a test area that is firm, level and free of obstruction.
2Be sure the battery pack is connected.
At the Ground Controls
3Pull out the platform and ground red Emergency Stop buttons to the on position.
4Turn the key switch to ground control.
5 Observe the diagnostic LED readout.
Result: The LED should look like the picture at right.
Test the Emergency Stop
6Push in the ground red Emergency Stop button to the off position.
Result: No functions should operate.
7Pull out the red Emergency Stop button to the on position.
Test the Up/Down Functions
The descent alarm and the motion alarm sound at 60 beeps per minute and sound at the chassis. The alarm that goes off when the machine is not level sounds at 180 beeps per minute and sounds at the chassis and in the platform.
8Do not hold the function enable button. Activate the platform up function.
Result: No function should operate.
9Push and hold the function enable button and activate the platform up function.
Result: The platform should raise.
10Push and hold the function enable button and activate the platform down function.
Result: The platform should lower. The descent alarm should sound while the platform is lowering.
Test the Auxiliary Lowering
To test machines equipped with a separate auxiliary lowering button next to the ground control panel, perform steps 11 through 13. For machines that are not equipped with a separate button, skip to step 14.
11Push and hold the function enable button and activate the platform up function. Raise the platform approximately 2 feet / 60 cm.
12Push and hold the auxiliary lowering button.
Result: The platform should lower. The descent alarm will not sound.
13Turn the key switch to platform control and go to step 17.
Machines not equipped with a separate auxiliary lowering button:
14Push and hold the function enable button and activate the platform up function. Raise the platform approximately 2 feet / 60 cm.
15Push and hold the function enable button. Activate the down function.
Result: The platform should lower. The descent alarm will not sound.
16 Turn the key switch to platform control.