At the Platform Controls

Test Emergency Stop

17Push in the platform red Emergency Stop button to the off position.

Result: No functions should operate.

18 Pull the red Emergency Stop button out to the on position.

Result: The green power light should come on.

Test the Horn

19 Push the horn button.

Result: The horn should sound.

Test the Function Enable Switch

20Do not hold the function enable switch on the control handle.

21Slowly move the control handle in the direction indicated by the blue arrow, then in the direction indicated by the yellow arrow.

Result: No functions should operate.

FUNCTION TESTS

Test the Up/Down Functions

22 Press the lift function select button.

23Press and hold the function enable switch on the control handle.

24Slowly move the control handle in the direction indicated by the blue arrow.

Result: The platform should raise.

25 Release the control handle.

Result: The platform should stop raising.

26Press and hold the function enable switch. Slowly move the control handle in the direction indicated by the yellow arrow.

Result: The platform should lower. The descent alarm should sound while the platform is lowering.

Part No. 82750

Genie GS-2668 DC and Genie GS-3268 DC

17

Image 19
Contents Operator’s Manual Contact us ContentsDo Not Operate Unless Safety RulesTip-over Hazards Electrocution HazardsGS-2668 DC Fall Hazards Bodily Injury Hazard Collision HazardsComponent Damage Hazards Decal Legend Explosion and Fire HazardsDamaged Machine Hazards Crushing HazardsTip-over Hazard Battery Safety Burn HazardsExplosion Hazards Component Damage HazardPage Platform Controls ControlsGround Control Panel StopFundamentals Pre-operation InspectionPre-operation Inspection Check the Hydraulic Oil Level MaintenanceMaintenance Symbols Legend Observe and ObeyCheck the Batteries Scheduled MaintenanceFunction Tests Test the Auxiliary Lowering At the Ground ControlsTest the Emergency Stop Test the Up/Down FunctionsTest the Horn Test the Function Enable SwitchAt the Platform Controls Test Emergency StopTest Drive and Braking Test the SteeringTest the Tilt Sensor Operation Test Limited Drive SpeedWorkplace Inspection Workplace InspectionEmergency Stop Operating InstructionsOnly use the machine as it was intended Operation From Ground Auxiliary LoweringOperation From Platform Fall Protection Drive Select SwitchError Indicator Light On Operation From Ground with ControllerTo Charge Battery Battery and Charger Instructions Observe and ObeyDry Battery Filling Charging Instructions Brake Release Operation Transport and Lifting InstructionsAxis Lifting InstructionsSecuring to Truck or Trailer for Transit Inspection for Decals with Words DecalsDecals Ground Controls Side Battery SideInspection for Decals with Symbols Battery Side Ground Controls D e l GS-2668 DC SpecificationsSpecifications Distributed By