Electrocution Hazards

This machine is not electrically insulated and will not provide protection from contact with or proximity to electrical current.

Maintain safe distances from electrical power lines and apparatus in accordance with applicable governmental regulations and the following chart.

Voltage

 

Minimum Safe

Phase to Phase

Approach Distance

 

Feet

Meters

 

 

0 to 300V

Avoid Contact

 

 

 

300V to 50KV

10

3.05

 

 

 

50KV to 200KV

15

4.60

 

 

 

200KV to 350KV

20

6.10

 

 

 

350KV to 500KV

25

7.62

 

 

 

500KV to 750KV

35

10.67

 

 

 

750KV to 1000KV

45

13.72

 

 

 

Allow for platform movement, electrical line sway or sag and beware of strong or gusty winds.

Keep away from the machine if it contacts energized power lines. Personnel on the ground or in the platform must not touch or operate the machine until energized power lines are shut off.

Do not operate the machine during lightning or storms.

Do not use the machine as a ground for welding.

Tip-over Hazards

Occupants, equipment and materials shall not exceed the maximum platform capacity or the maximum capacity of the platform extension.

Maximum capacity - GS-2668 DC

Platform retracted

1250

lbs

567 kg

 

 

 

 

Platform extended - Platform only

950

lbs

431 kg

Platform extended - Extension only

300

lbs

136 kg

 

 

 

Maximum occupants - ANSI and CSA

 

4

 

 

 

 

Maximum occupants - Australia

 

 

 

Outdoor use

 

 

4

Indoor use only

 

 

4

 

 

 

 

1250 lbs / 567 kg Extension only

Platform only

300 lbs / 136 kg 950 lbs / 431kg

 

 

 

 

Maximum capacity - GS-3268 DC

 

 

 

 

 

 

 

Platform retracted

1000

lbs

454 kg

 

 

 

 

Platform extended - Platform only

700

lbs

318 kg

Platform extended - Extension only

300

lbs

136 kg

 

 

 

Maximum occupants - ANSI and CSA

 

4

 

 

 

 

Maximum occupants - Australia

 

 

 

Outdoor use

 

 

2

Indoor use only

 

 

4

 

 

 

 

1000 lbs / 454 kg Extension only

Platform only

300 lbs / 136 kg

700 lbs / 318 kg

2

Genie GS-2668 DC and Genie GS-3268 DC

Part No. 82750

Image 4
Contents Operator’s Manual Contents Contact usSafety Rules Do Not Operate UnlessElectrocution Hazards Tip-over HazardsGS-2668 DC Fall Hazards Bodily Injury Hazard Collision HazardsComponent Damage Hazards Explosion and Fire Hazards Damaged Machine HazardsCrushing Hazards Decal LegendBattery Safety Burn Hazards Explosion HazardsComponent Damage Hazard Tip-over HazardPage Controls Platform ControlsStop Ground Control PanelPre-operation Inspection FundamentalsPre-operation Inspection Maintenance Maintenance Symbols LegendObserve and Obey Check the Hydraulic Oil LevelScheduled Maintenance Check the BatteriesFunction Tests At the Ground Controls Test the Emergency StopTest the Up/Down Functions Test the Auxiliary LoweringTest the Function Enable Switch At the Platform ControlsTest Emergency Stop Test the HornTest the Steering Test Drive and BrakingTest Limited Drive Speed Test the Tilt Sensor OperationWorkplace Inspection Workplace InspectionEmergency Stop Operating InstructionsOnly use the machine as it was intended Operation From Ground Auxiliary LoweringOperation From Platform Drive Select Switch Error Indicator Light OnOperation From Ground with Controller Fall ProtectionTo Charge Battery Battery and Charger Instructions Observe and ObeyDry Battery Filling Charging Instructions Transport and Lifting Instructions Brake Release OperationLifting Instructions AxisSecuring to Truck or Trailer for Transit Decals Inspection for Decals with WordsGround Controls Side Battery Side DecalsInspection for Decals with Symbols Battery Side Ground Controls Specifications D e l GS-2668 DCSpecifications Distributed By