Genie GS-3268, GS-2668 DC Operation From Ground with Controller, Fall Protection, After Each Use

Page 25

Third Edition • Third Printing

Operator's Manual

 

 

 

 

 

 

Drive Select Switch

Machine on incline symbol:

Low range operation for inclines

Error Indicator Light On

If the error indicator light is on, push in and pull out the red Emergency Stop button to reset the system.

If the light stays red, tag and remove the machine from service.

To Extend and Retract Platform (Manual Platform Extension)

1Lift the platform extension lock handle to the horizontal position.

2Push the platform extension lock handle to extend the platform to the desired position.

Do not stand on the platform extension while trying to extend it.

3 Lower the platform extension lock handle.

Operation From Ground with Controller

Maintain safe distances between the operator, the machine and fixed objects.

Be aware of the direction the machine will travel when using the controller.

OPERATING INSTRUCTIONS

Fall Protection

Personal fall protection equipment (PFPE) is not required when operating this machine. If PFPE is required by job site or employer rules, the following shall apply:

All PFPE must comply with applicable governmental regulations and must be inspected and used in accordance with the manufacturer’s instructions.

After Each Use

1Select a safe parking location—firm level surface, clear of obstructions and traffic.

2Lower the platform.

3Turn the key switch to the off position and remove the key to secure from unauthorized use.

4Chock the wheels.

5Charge the batteries.

Part No. 82750

Genie GS-2668 DC and Genie GS-3268 DC

23

Image 25
Contents Operator’s Manual Contact us ContentsDo Not Operate Unless Safety RulesTip-over Hazards Electrocution HazardsGS-2668 DC Fall Hazards Bodily Injury Hazard Collision HazardsComponent Damage Hazards Damaged Machine Hazards Explosion and Fire HazardsCrushing Hazards Decal LegendExplosion Hazards Battery Safety Burn HazardsComponent Damage Hazard Tip-over HazardPage Platform Controls ControlsGround Control Panel StopFundamentals Pre-operation InspectionPre-operation Inspection Maintenance Symbols Legend MaintenanceObserve and Obey Check the Hydraulic Oil LevelCheck the Batteries Scheduled MaintenanceFunction Tests Test the Emergency Stop At the Ground ControlsTest the Up/Down Functions Test the Auxiliary LoweringAt the Platform Controls Test the Function Enable SwitchTest Emergency Stop Test the HornTest Drive and Braking Test the SteeringTest the Tilt Sensor Operation Test Limited Drive SpeedWorkplace Inspection Workplace InspectionEmergency Stop Operating InstructionsOnly use the machine as it was intended Operation From Ground Auxiliary LoweringOperation From Platform Error Indicator Light On Drive Select SwitchOperation From Ground with Controller Fall ProtectionTo Charge Battery Battery and Charger Instructions Observe and ObeyDry Battery Filling Charging Instructions Brake Release Operation Transport and Lifting InstructionsAxis Lifting InstructionsSecuring to Truck or Trailer for Transit Inspection for Decals with Words DecalsDecals Ground Controls Side Battery SideInspection for Decals with Symbols Battery Side Ground Controls D e l GS-2668 DC SpecificationsSpecifications Distributed By