Generac 004692-0 owner manual Spark Plugs, Battery Maintenance

Page 20

Section 4 — Maintenance

Air-cooled 8.5 kW Generator

Figure 4.4 — 12 kW and 15 kW Engine

Air Cleaner

Screw

Cover

Filter

4.6SPARK PLUG(S)

Reset the spark plug(s) gap or replace the spark plug(s) as necessary. See Section 4.11 (Page 19) for maintenance requirements.

1.Clean the area around the base of the spark plug(s) to keep dirt and debris out of the engine. Clean by scraping or washing using a wire brush and commercial solvent. Do not blast the spark plug(s) to clean.

2.Remove the spark plug(s) and check the condi- tion. Replace the spark plug(s) if worn or if reuse is questionable. See Section 4.11 (Page 19) for recommended inspection.

3.Check the spark plug gap using a wire feeler gauge, carefully bending the ground electrode (Figure 4.5).

Figure 4.5 – Setting the Spark Plug Gap

SET PLUG GAP AT 0.50 mm

(0.020 inch)

4.7BATTERY MAINTENANCE

The battery should be inspected per the “Service Schedule,” Section 4.11 (Page 19). The following pro- cedure should be followed for inspection:

1.Inspect the battery posts and cables for tightness and corrosion. Tighten and clean as necessary.

2.Check the battery fluid level of unsealed batteries and, if necessary, fill with DISTILLED WATER ONLY. DO NOT USE TAP WATER IN BATTERIES.

3.Have the state of charge and condition checked. This should be done with an automotive-type bat- tery hydrometer.

DANGER

Do not dispose of the battery in a fire. The battery is capable of exploding.

A battery presents a risk of electrical shock and high short circuit current. The following precautions are to be observed when working on batteries:

Remove watches, rings or other metal objects;

Use tools with insulated handles;

Wear rubber gloves and boots;

Do not lay tools or metal parts on top of the battery; and

Disconnect charging source prior to connecting or dis- connecting battery terminals.

Do not open or mutilate the battery. Released

!electrolyte has been known to be harmful to the skin and eyes, and to be toxic.

The electrolyte is a dilute sulfuric acid that is

!harmful to the skin and eyes. It is electrically conductive and corrosive. The following procedures are to be observed:

Wear full eye protection and protective clothing;

Where electrolyte contacts the skin, wash it off immediately with water;

Where electrolyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention; and

Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to use a solution of 1 pound (500 grams) bicarbonate of soda to 1 gallon (4 liters) or water. The bicar- bonate of soda solution is to be added until the evidence of reaction (foaming) has ceased. The resulting liquid is to be flushed with water and the area dried.

18 Generac® Power Systems, Inc.

Image 20
Contents Installation Introduction Authorized Dealer LocationTroubleshooting General Hazards Electrical Hazards Standards IndexProtection Systems System SET LEDUNPACKING/INSPECTION Your Generator 8.5 kW, V-Twin GT-990 EngineSpecifications GeneratorFuel Consumption Reconfiguring Fuel SystemFuel Requirements Recommendations Battery Installation BatteryTransfer Switch LocationElectrical Checks Check Transfer Switch OperationBefore Initial START-UP Generator Tests Under Load Adjusting the Regulator Natural GAS only Checking Automatic OperationEngine Governor Adjustment Voltage Regulator AdjustmentBREAK-IN Procedure Automatic Transfer OperationManual Position Auto PositionSequence of Automatic Operation Manual Transfer OperationSetting the Exercise Timer Transfer Back to Utility Power SourceLOW OIL Pressure Switch High Temperature SwitchChecking the Engine OIL Level OverspeedOIL Change Procedure Changing the Engine OILChanging the OIL Filter Engine OIL RecommendationsBattery Maintenance Spark PlugsAdjusting Valve Clearance Cooling SystemOUT of Service Procedure Return to ServiceRemoval from Service Corrosion ProtectionService Schedule Be performed by your nearest Generac Authorized DealerTroubleshooting Guide Problem Cause CorrectionMounting Dimensions Electrical Data Customer Connection TX TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA Dual SEC 1VA Exploded Views and Parts Lists QTY Description Exploded Views and Parts Lists ADAPTOR, Engine Exploded Views and Parts Lists Description QTY 138 122 KNOB, AIR Cleaner 4417 3930 Circuit Breaker 30 X 2 240V SQD Transfer Switch Home Standby Engine only PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule This Warranty Shall not Apply to the Following