Farm Duty | Model: DLC60 |
Alternator Specifications
Manufacturer | Stamford/Newage |
Type | |
Model | UC224G |
Leads | 4 |
Voltage regulator | AVR |
Voltage regulation | 1/2% |
Insulation material: Rotor | Class H |
Insulation material: Stator | Class H |
Temperature rise | 125C, Standby |
Total harmonic distortion | <5% |
Bearing: quantity, type | 1, Sealed |
Coupling type | Flexible disc |
One step load acceptance | 100% of Rating |
Warranty: Limited 3 year warranty.
1 year or 3000 hours parts and labor.
3 years or 3000 hours parts.
Baldor reserves the right to repair or replace unit.
Alternator Features
Brushless design
Class H insulation used throughout
All wound components impregnated with varnishes and resins to protect against harsh environment Alternator complies with temperature rise standards: NEMA, IEEE and ANSI
Dynamically balanced rotors
Controller Features
PowerPAC 4
Hi temp, low oil pressure, overspeed and overcrank indicators
AC Voltage, amperage and hertz meters
Oil pressure, water temperature and battery gauges Hour meter
Panel lights
Engine Specifications
| Engine Data |
|
|
|
|
|
|
|
|
|
| Engine Features |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Manufacturer |
|
| Perkins |
| • Mechanical governor - speed control to ISO | |||||||||||||||
| Model |
|
|
| • |
|
|
|
| ||||||||||||
| Cylinders |
|
| 4 |
| • Fuel |
|
|
|
| |||||||||||
| Cycle |
|
|
| • |
|
|
|
| ||||||||||||
| Induction system |
|
| Turbocharged |
| • Oil cooler |
|
|
|
| |||||||||||
| Displacement, L (cu. in.) |
|
| 3.99 (243.5 cu. in.) |
| • Thermostat controlled cooling system |
|
|
| ||||||||||||
| Bore and Stroke |
|
| 100.0 MM x 127.0 MM 3.94 x 5 |
| • Gear driven water pump |
|
|
|
| |||||||||||
| Compression Ratio |
|
| 17.25:1 |
|
|
|
| • 12V engine alternator |
|
|
|
| ||||||||
| Lubrication capacity |
|
| 8.4 liters (9 qts.) |
| • 12V starter motor |
|
|
|
| |||||||||||
| Cooling capacity (incl. radiator) |
|
| 18.8 liters (23.4 qts.) |
| • Single side servicing |
|
|
|
| |||||||||||
| Weight without fuel - Net |
|
| 1945 |
|
|
|
|
|
| Engine Performance |
|
|
|
| ||||||
| Weight without fuel - Shipping |
|
| 2030 |
|
|
|
|
|
| Continuous | Standby | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Warranty: 2 year limited per manufacturer |
|
|
|
| Rated RPM | 1800 | 1800 |
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| 60 HZ |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Size: Length x Width x Height |
|
|
|
|
|
|
|
|
|
| Net BHP at rated | 95 | 86 |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
| 783⁄4" x 36" x 45" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Baldor Generators | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3815 Oregon Street | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Oshkosh, WI 54902 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fax | |||
|
|
|
|
|
| 45.00" |
|
|
|
|
|
|
|
|
|
| www.baldor.com | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Distributed by: | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 36.00" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 78.75" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| Drawing is for reference only: Contact your dealer for detailed information. |
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|