Baldor ISO9001 manual Ż ż for Gasoline or Diesel Powered Generator Sets ż ż ż ż

Page 5

ƇAlways treat the electrical circuits as if they were energized.

ƇDisconnect all leads plugged into the unit Prior to working on it.

ƇHave the electrical circuits serviced only by qualified technicians.

ƇInspect wiring frequently and replace frayed, broken or poor leads.

ƇDo not connect this unit to any building's electrical system unless you utilize an approved transfer switch or the main service entrance switch has been disconnected and locked open.

ƇCircuit overload protection must be provided in accordance with national electrical codes and local regulations.

ƇCheck GFCI Receptacles monthly by using the "Test" and "Reset" buttons designed into them.

ƇDepending on your application it may be mandatory to ground or not ground this unit to earth ground. Comply with local electrical codes.

ż ż ż ż FOR GASOLINE OR DIESEL POWERED GENERATOR SETS ż ż ż ż

ƇOperate the generator set on a level surface. If the generator set is tilted, fuel spillage may result.

ƇHandle fuel with care. It is highly flammable. Use only clean, properly marked and approved safety containers for refueling and storing fuel.

ƇStop the engine and allow it to cool before refueling.

ƇDo not overfill the fuel tank. Only fill the tank to within 1/2" of the top of the tank to allow space for fuel expansion.

ƇIf fuel is spilled, wipe it up carefully and wait until the fuel has dried before starting the engine.

ƇMake sure the fuel cap is properly closed after refueling.

ƇNever operate the generator set while smoking.

ƇNever operate the generator set near an open flame.

ƇNever store the generator set with fuel in the tank indoors or in an enclosed, poorly ventilated enclosure where fuel fumes may reach an open flame, electrical spark or pilot light as on a furnace, water heater, clothes dryer, etc.

ƇWhen transporting over long distances or rough roads, drain the fuel tank to prevent leakage and spillage.

-iv -

Image 5
Contents Standby Permanent Mount Series Generator Forward Page Page Ż ż for Gasoline or Diesel Powered Generator Sets ż ż ż ż Ż ż for Gasoline or Diesel Powered Generator Sets ż ż ż ż Standby PERMANENT- Mount Series Generator Baldor Baldor Generator Features OptionsEngine Specifications Farm Duty 1-Phase Model DLC25Model D50 PowerPAC Farm Duty 1-Phase Model DLC50Model D60 Engine Specifications Farm Duty 1-Phase Model DLC60Model D75 Engine Data Farm Duty 1-Phase Model DLC75Model D100 Model DLC100 Farm Duty 1-PhaseModel D130 Farm Duty 1-Phase Model DLC130 Electrical Connection Information Hard Wire Load Terminal BlockConnection Information Standby Permanent Mount Series Generator Generator Mounting RequirementsEngine Cooling Requirements Engine Cooling AIR Backpressure must not exceed 20 of water column HOT Exhaust GasesPage Generator END Cooling AIR Building VentilationBuilding Ventilation Exhaust Piping Exhaust RequirementsExhaust Thimble Minimum O.D Exhaust Piping Thru Walls and RoofsDouble Thimble Roof Outlet Details Control Panel Operation Function Page Page Operation Starting Operation Cranking Control LOW Voltage No VoltageOverheating Fluctuating VoltageHigh Voltage Mechanical Noise Generator Frame Produces Shock When TouchedTroubleshooting Engine Limited Warranty Warranty Period Limitations RPM Distributor Information END User / Owner InformationKVA CurrentPre Start-Up Check List Start-Up Procedure Oregon Street Oshkosh WI Phone 920-239-4200 Fax California Proposition 65 Warning Oregon Street Oshkosh WI Phone 920 236-4200 Fax 920