Intel STL2 Environmental Limits, Use Only for Intended Applications, Installation Precautions

Page 96

Regulatory and Integration Information

STL2 Server Board TPS

8.2.5Use Only for Intended Applications

This product was evaluated for use in ITE computers that will be installed in offices, schools, computer rooms and similar locations. The suitability of this product for other product categories other than ITE applications, (such as medical, industrial, alarm systems, and test equipment) may require further evaluation.

8.2.6Installation Precautions

During the installation and testing of the board, the user should observe all warnings and cautions in the installation instructions. To avoid injury, be aware of the following:

Sharp pins on connectors.

Sharp pins on printed circuit assemblies.

Rough edges and sharp corners on the chassis.

Hot components (like processors, voltage regulators, and heat sinks).

Damage to wires that could cause a short circuit.

Observe all warnings and cautions that instruct you to refer computer servicing to qualified technical personnel.

WARNING: Do not open the power supply. There is risk of electric shock and burns from high voltage and rapid overheating. Refer servicing of the power supply to qualified technical personnel.

8.3Environmental Limits

8.3.1System Office Environment

Table 8-2. Office System Environment Summary

 

 

Operating Temperature

+10°C to +35°C with the maximum rate of change not to exceed

 

10°C per hour

Non-Operating Temperature

-40°C to +70°C

 

 

Non-Operating Humidity

95%, non-condensing @ 30°C

Altitude De-rate

0.5° per 1000 feet

Acoustic noise

< 47 dBA with one power supply @ 28+-2°C

 

 

< 50 dBA with two power supplies @ 28+-2°C

 

< 55 dBA with three power supplies @ 28+-2°C

 

 

 

Operating Shock

No errors with a half sine wave shock of 2G (with 11 millisecond

 

duration)

 

 

Package Shock

System operational after a 30" free fall, cosmetic damage may

 

be present

ESD

20KV per Intel Environmental Test Specification

 

 

8-88

Image 96
Contents STL2 Server Board Revision September 22 Enterprise Platforms GroupRevision History STL2 Server Board TPS Date Revision Modifications NumberTable of Contents Basic Input Output System Bios Jumpers and ConnectorsTable of ContentsSTL2 Server Board TPS Power Consumption STL2 Server Board TPSTable of ContentsEmbedded NIC PCI Signals List of Figures STL2 Server Board TPSList of Tables STL2 Server Board TPS List of TablesList of TablesSTL2 Server Board TPS STL2 Server Board Feature Overview PurposeAudience STL2 Server Board TPS IntroductionSTL2 Server Board Block Diagram Introduction STL2 Server Board TPSSTL2 Server Board Block Diagram This page intentionally left blank Intel Pentium III Processor Subsystem Supported Processor TypesSTL2 Server Board Supported Processors Speed FSB Frequency Cache Size CoreProcessor Bus Termination / Regulation / Power Dual Processor Operation3 PGA370 Socket Termination PackageServerWorks ServerSet III LE Chipset Memory∙ NB6635 North Bridge 3.0LE ∙ IB6566 South BridgePCI I/O Subsystem 1 64-bit / 66 MHz PCI SubsystemUltra160 / Ultra WideSCSI Controller Embedded Scsi Supported PCI Commands Be 30 L Command Target MasterScsi Transfer Speeds AIC-7899 Support2 32-bit/33 MHz PCI Subsystem Network Interface Controller NICSupported Network Features Video Controller PCI Signals Video ControllerVideo Controller Supported PCI Commands BE30L Command Type Target MasterResolution Refresh Rate Hz Colors Standard VGA Modes2.3 IB6566 South Bridge PCI InterfacePower Management Chipset Support ComponentsLegacy I/O Super I/O National* PC97317VUL Compatibility Interrupt ControlKeyboard and Mouse Connectors Power Management ControllerSerial Ports Parallel PortBios Flash External Device ConnectorsDefault I/O Apic Interrupt RoutingSTL2 Baseboard Interrupt Routing Diagram PIC mode STL2 Baseboard Interrupt Routing Diagram Symmetric mode Device Bus Number Device Number Slot ID Signal 2316 1511 PCI IdsRelationship between PCI IRQ and PCI Device STL2 PCI IDsRevision Page Baseboard Management Controller STL2 Server Board TPS Server ManagementHardware Sensors Server Management STL2 Server Board TPSSensor Number Sensor Type Monitoring Device Sensor Type Sensor-Specific Event Remarks Code Offset PCI Serr Acpi EMPAC Link Mode Wake On LAN FunctionBios Overview STL2 Server Board TPS Basic Input Output System BiosSystem Bios Flash Update UtilityBasic Input Output System Bios STL2 Server Board TPS System Flash ROM LayoutSetup Utility Configuration Utilities OverviewSetup Utility Operation Setup Utility ScreenEntering Setup Utility Keyboard Command BarEnter Execute Command F1 HelpF9 Setup Defaults ← → Select MenuF5/- Change Value F6/+ Change ValueMain Menu Selections Main Menu SelectionsProcessor Settings Submenu Selections STL2 Server Board TPSBasic Input Output System BiosChoices or Display Feature Only Description User Setting Primary Master and Slave Adapters Submenu SelectionsAdvanced Menu Selections Advanced Menu SelectionsMemory Reconfiruation Submenu Selections Peripheral Configuration Submenu Selections PCI Device Submenu Selections Option ROM Submenu Selections10. Numlock Submenu Selections Security Menu Selections 11. Security Menu Selections12. Secure Mode Submenu Selections System Hardware Menu Selections13. Server Menu Selections 14. Wake On Events Submenu SelectionsBoot Menu Selections 16. Boot Menu Selections17. Boot Device Priority Selections 15. Console Redirection Submenu SelectionsCmos Memory Definition Exit Menu Selections18. Hard Drive Selections 19. Removable Devices SelectionsCmos Default Override Flash Update UtilityLoading the System Bios User-supplied Bios Code Support OEM CustomizationMSB Scan Point Definitions 21. User Binary Area Scan Point DefinitionsScan Point Mask RAM/Stack/BDA Video/Keyboard Recovery Mode Language AreaOEM Splash Screen 22. Format of the User Binary Information StructureError Messages and Error Codes Post Codes23. Port-80h Code Definition Code Meaning24. Standard Bios Port-80 Codes Beeps ReasonPage Revision Post Error Codes and Messages 25. Recovery Bios Port-80 Codes26. Post Error Messages and Codes Basic Input Output System BIOSSTL2 Server Board TPSRevision Beeps Error Cause Recommended Action Identifying Bios and BMC Revision Levels Bios Revision Level IdentificationBMC Revision Level Identification Adaptec Scsi Utility Configuration Settings Adaptec Scsi UtilityRunning the Scsi Utility Bus Device Channel Selected Scsi Adapter27. Adaptec Scsi Utility Setup Configurations Option Recommended Setting or User Setting Display OnlyExiting Adaptec Scsi Utility This page intentionally left blank Page Jumper and connector location key for Figure STL2 Server Board TPS Jumpers and ConnectorsJumpers and Connectors STL2 Server Board TPS Back Panel location key for FigureSetting CMOS/Password Clear Jumper Block 1J15 Jumper BlocksClearing and Changing a Password Jumper Block 1J15 SettingsClearing Cmos Perfoming a Bios Recovery Boot Setting Processor Frequency Jumper Block 5E1Setting Configuration Jumper Block 1L4 Jumper Block 5E1 SettingsJumper Block 1J15 Default Settings Connectors Setting Configuration Jumper Block 6AJumper Block 1L4 Settings Jumper Block 6A SettingsMain ATX Power Connector P33 Auxilary ATX Power Connector P343 I2C Power Connector P37 System Fan Connectors P29, P27, P11 Processor Connectors P12, P36Speaker Connector P31 Speaker Connector P25Diskette Drive Connector P20 14. Video Port Connector PinoutSvga Video Port Keyboard and Mouse Connectors Parallel PortSerial Ports COM1 and COM2 13 RJ-45 LAN Connector USB Connectors18. RJ-45 LAN Connector Signals 19. USB ConnectorsUltra Scsi Connector P9 Ultra160 Scsi Connector P820. Ultra Scsi Connector Pinout 21. Ultra160 Scsi ConnectorIDE Connector P19 22. IDE Connector PinoutJumpers and Connectors STL2 Server Board TPS Pin Signal 18 32-Bit PCI Connector 23 -Bit PCI Connector Pinout19 64-Bit PCI Connector 24 -Bit PCI Connctor PinoutFront Panel 24-pin Connector Pinout P23 25. Front Panel 24-pin Connector PinoutPin Description Jumpers and Connectors STL2 Server Board TPS This page intentionally left blank Page Calculated Power Consumption STL2 Server Board Calculated Power ConsumptionMeasured Power Consumption STL2 Server Board Measured Power ConsumptionPower Consumption STL2 Server Board TPS Devices +5V +12V Total WattageMechanical Specifications STL2 Server Board TPS Mechanical SpecificationsMechanical Specifications STL2 Server Board TPS Safety Regulations Regulatory ComplianceRegulation Title Installation Instructions Ensure Host Computer and Accessory Module CertificationsEnsure EMC Prevent Power Supply Overload Place Battery Marking on ComputerEurope United StatesInstallation Precautions Environmental LimitsUse Only for Intended Applications System Office EnvironmentSystem Environmental Testing This page intentionally left blank STL2 Server Board TPS Glossary Term DefinitionReference Documents Reference Documents STL2 Server Board TPSIndex STL2 Server Board EPS IndexIndex STL2 Server Board TPS Revision

STL2 specifications

The Intel STL2, known as the Intel Storage Technology Level 2, is a robust solution designed to elevate storage management and performance for enterprise-level applications. This next-generation system is specifically tailored for organizations that demand high reliability, scalability, and efficiency in their storage solutions.

One of the primary features of the Intel STL2 is its advanced data protection mechanisms. With integrated RAID (Redundant Array of Independent Disks) support, it ensures that data remains safe, even in the event of hardware failure. RAID configurations can be easily set up and managed, allowing businesses to choose the right balance between performance and redundancy based on their unique requirements.

In terms of performance, the STL2 leverages cutting-edge SSD (Solid State Drive) integration to provide high-speed data access and reduced latency. This capability is essential for modern applications that require quick retrieval of large volumes of data, making it suitable for environments like data analytics, AI, and cloud computing.

Scalability is another significant characteristic of the Intel STL2. It is designed to grow alongside an organization’s needs, supporting a diverse range of storage architectures. Whether a company is looking to expand its data center or transition to hybrid cloud solutions, the STL2 can accommodate additional storage resources effortlessly, ensuring that performance does not degrade as storage demands increase.

Moreover, the STL2 features advanced automation and management tools that simplify storage operations. The system allows for real-time monitoring and analytics, providing insights into storage health, performance metrics, and capacity forecasts. This level of visibility enables IT teams to optimize resource utilization and proactively address potential issues before they become critical.

Another notable technology integrated into the STL2 is Intel’s Open Storage Architecture, which promotes interoperability with various software and hardware platforms. This open approach facilitates seamless integrations with existing systems and enhances flexibility within dynamic IT environments.

Lastly, Intel STL2 prioritizes energy efficiency. Its design minimizes power consumption without sacrificing performance, helping organizations reduce their operational costs and carbon footprint.

In summary, the Intel STL2 stands out in the competitive landscape of storage solutions with its focus on data protection, high performance, scalability, advanced management features, open architecture compatibility, and energy efficiency. These characteristics make it an ideal choice for businesses looking to enhance their data storage capabilities in a rapidly evolving digital landscape.