Intel 536EX manual Intel Confidential, Data Mode AT COMMANDS, +Esr, +Etbm, 1, 1

Page 50
+ESR

Data Mode AT COMMANDS

Table 18. Data Mode Command Descriptions (Continued)

Command

Default

 

Description

 

 

 

 

 

Selective Repeat: Controls the use of selective repeat (SREJ) option in V.42.

+ESR

1

0

Do not use SREJ

1

Use SREJ if available in remote DCE; continue without it if not

 

 

 

 

2

Use SREJ if available in remote DCE; disconnect if SREJ is not available

 

 

 

 

 

Call Termination Buffer Management: Controls the handling of data remaining in the DCE buffers upon

 

 

call termination. It accepts three numeric parameters:

 

 

Syntax:

 

 

+ETBM = <pending TD>, <pending RD>, <timer>

 

 

<pending TD> controls how previously transmitted data remaining in the DCE buffers should be handled

 

 

when the local DTE requests disconnection of the call.

 

 

0

Discard all buffered data immediately and disconnect

 

 

1

Attempt until all data is delivered and acknowledged (ignoring timer); if remote DCE

 

 

 

disconnects discard remaining data

+ETBM

1, 1, 20

2

Attempt until all data is delivered and acknowledged; if timer expires or remote DCE

 

disconnects, discard remaining data

 

 

<pending RD> controls how previously received data remaining in the DCE buffers should be handled

 

 

when the remote DCE disconnects the call.

 

 

0

Discard all buffered data immediately and disconnect

 

 

1

Attempt until all data is delivered (ignoring timer); if local DTE requests disconnect discard

 

 

 

remaining data

 

 

2

Attempt until all data is delivered; if timer expires or local DTE requests disconnect discard

 

 

 

remaining data

 

 

<timer> sets a maximum time limit that the DCE will attempt to deliver the buffered data before

 

 

disconnecting and discarding the remaining

 

 

0–30

Delivery timer value in seconds

 

 

 

 

 

Request Complete Capabilities List: This extended-format command causes the DCE to transmit a list

 

 

of additional capabilities commands.

+GCAP

none

 

AT+GCAP

 

 

 

+GCAP: +FCLASS,+MS,+ES,+DS

 

 

 

OK

 

 

 

 

 

Identify Country of Installation: This extended command is used to indicate and select the country of

 

 

installation for the DCE. The DTE may use this value to determine country-specific functions. To

 

 

determine what countries the DCE supports, issue the AT+GCI=? command. Refer to the ITU-T T.35

+GCI=m

see ‘m’

recommendation for the details on what country code is used for each country.

 

 

Default: country of installation

 

 

m = country code, e.g., United States

 

 

 

AT+GCI=B5

 

 

 

 

 

Identify Modem Manufacturer: This command causes the DCE to send a message to the DTE

 

 

indicating the DCE manufacturer. This command is identical to AT+FMFR? and AT+FMI.

+GMI

none

 

AT+GMI

 

 

 

Intel Corporation

 

 

 

OK

 

 

 

 

 

Identify Product Model: This command causes the DCE to report the modem chipset name. This

 

 

command is identical to AT+FMDL? and AT+FMM commands.

+GMM

none

 

AT+GMM

 

 

 

Intel 536EP V.92 Modem

 

 

 

OK

 

 

 

 

NOTE: An asterisk (*) denotes the factory-default setting.

50

536EX Chipset Developer’s Manual

Intel Confidential

Image 50
Contents January 536EX ChipsetDeveloper’s Manual Intel Confidential 536EX Chipset Developer’s ManualContents ContentsFigures Tables Revision Revision HistoryDate DescriptionIntroduction 1.1Controllerless Modem Driver OverviewUser applications Figure 1. WDM Driver Block Diagram1.1.2Windows 95 and Windows Kernel - ring0Figure 2. VxD Mini Port Driver Block Diagram 1.2V.90/V.92 and V.34 Data Modes1.3Modem Connection Overview Table 3. DCE-to-ISPData Rates for V.90 Mode Table 1. DTE-to-DCEData Rates for Each ModeTable 2. DCE-to-DCEData Rates for Each Mode 1.4.1Sending Commands Table 4. DTE-ModemData Rate Response Codes1.4.2AT Escape Sequences 1.4.3Dial ModifierTable 5. Data Mode Command Summary AT Command Summary TablesAT Command Summary Tables Table 5. Data Mode Command Summary Continued Result code type Intel Confidential Generate data mode calling tone Table 6. V.44/V.42/V.42 bis MNP Command Summary connect state, transmits Table 7. Fax Identity Command Summary Table 8. Fax Class 1 Command SummaryTable 9. IS-101Voice Command Summary Table 10. Voice DTE→DCE Character PairsTable 10. Voice DTE→DCE Character Pairs Continued Table 11. Voice DTE←DCE Character PairsTable 13. S-RegisterSummary Table 11. Voice DTE←DCE Character Pairs ContinuedTable 12. Dial Modifiers Table 13. S-RegisterSummary Continued Data Mode AT COMMANDS Data Mode AT COMMANDSATW0 Table 14. Data Reporting Wn MappingFigure 3. Example of a Remote Connection •ATW2Examples +FMFR?, +FMDL?, +FREV? 3.8Modem-to-ModemConnection Data Rates 3.6Online Command Mode Escape Codes, On3.7Hanging Up Hn, S10, Zn, &D2 536EX Chipset Developer’s Manual +VCID=1 +PMH=0+PCW=0 +++AT536EX Chipset Developer’s Manual hook to connect the call. Now you can answer the phone and talk. After completing your voice conversation, the modem will issue another +PMHF and ATO command to initiate a Quick Connect. If the server rejects the request to go on hold, the user can stay on line ATO command issued or disconnect from his initial data connection ATH command issued Table 16. Supported Modulation Types 3.9Diagnostic Testing S18, &Tn 3.9.1Local Analog Loopback AT&T1Figure 6. Local Analog Loopback Test 3.9.2Local Analog Loopback With Self-TestAT&T8LOCAL MODEM Local Modem or Test Modem3.10.1Time-IndependentEscape Sequence Licensing Requirements for Hayes Escape Sequencechar1 = char2 = char3 = escape character S2 <char1><char2><char3><AT command><contents of S3>Format Table 18. Data Mode Command Descriptions 3.10.2Hayes* Escape Sequence536EX Chipset Developer’s Manual Sn=x 536EX Chipset Developer’s Manual Data Mode AT COMMANDSIntel Confidential Intel Confidential AT&V0 536EX Chipset Developer’s Manual Definition Command DefaultIndication 1, 0, 536EX Chipset Developer’s Manual 1, 1, +ESR+ETBM +IFC +GMR+GSN +ILRR=mmodulations +MS=m <carrier>Description see ‘m’<value> +PHSW=+PMHF +PMHR536EX Chipset Developer’s Manual Table 19. Operating Modes Error Correction and Data Compression4Error Correction and Data Compression Table 20. Resulting +ES Connection Types NOTES536EX Chipset Developer’s Manual Error Correction and Data CompressionIntel Confidential 536EX Chipset Developer’s Manual +DS=m +DR=mdirection <max string>3768 +EFCS=m+ER=m +ES=m 5.2Fax Class 1 Commands Fax Class 1 AT Commands5.1Fax Identity Commands Fax Class 1 AT CommandsTable 23. <mod> Selection Table Figure 8. T.30 HDLC Frame Format Table 24. Fax Mode Command Descriptions Refer to Table 23 on page Table 24. Fax Mode Command Descriptions Continued+FRH=m shown in Table 23 on page+FTH=m IS-101Voice Mode AT Commands IS-101Voice Mode AT Commands6.2Relay Control Table 25. Voice Mode Command Descriptions6.1DTMF Detection Reporting +FLO=m m = <deassert>, <assert>m=<enable>, <report> +VDR=mm = <mask> +VEM=mIntel Confidential +VIP Preassigned Voice I/O Labels +VLS=mVoice I/O Primitive Codes Relay/Playback Control: cont+VSD=m +VRXm = <sds>, <sdi> Transmission: Range: m= <cml>, <vsr>, <scs>, <sel>+VSM=m Compression Method Selection: cont +VSP=mfactory default is ‘0’ +VTS=m noneDescription CommandDefault DTMF and Tone Generation: contS-Registers S-RegistersTable 26. S-RegisterCommand Descriptions 536EX Chipset Developer’s Manual Intel ConfidentialS-Registers 536EX Chipset Developer’s Manual Intel ConfidentialS-Registers 536EX Chipset Developer’s Manual Intel ConfidentialS-Registers 536EX Chipset Developer’s Manual Table 27. Caller ID Tags for Formatted Reporting Caller IDCaller ID <DLE> R RING DATE = TIME = NMBR = NAME = DOE JOHN MESG =RING RING NMBR =Parallel Host Interface 16C450/16C550A UART Parallel Host Interface 16C450/16C550AUART Figure 11. UART Emulation in Intelsdb.VxDUART Transmitter Flow Diagram UART Receiver Flow DiagramADDRESS REGISTERBIT NUMBER NAMEFigure 14. Scratch Register SCR 9.2.1Scratch Register SCR9.2.2Modem Status Register MSR Figure 15. Modem Status Register MSR9.2.3Line Status Register LSR Figure 16. Line Status Register LSRFigure 17. Modem Control Register MCR 9.2.4Modem Control Register MCR9.2.5Line Control Register LCR Figure 18. Line Control Register LCRFigure 19. FIFO Control Register FCR 9.2.6FIFO Control Register FCRRegister Table 28. Interrupt Control Functions 9.2.7Interrupt Identity Register IIRFigure 20. Interrupt Identity Register IIR 9.2.9Transmitter Holding Register THR 9.2.8Interrupt Enable Register IERFigure 21. Interrupt Enable Register IER Figure 22. Transmitter Holding Register THRFigure 23. Receiver Buffer Register RBR 9.2.10Receiver Buffer Register RBR9.2.11Divisor Latch Registers DLM and DLL Figure 24. Divisor Latch Registers DLM and DLL9.3.2FIFO Polled Mode Operation 9.316C550A UART FIFO Operation9.3.1FIFO Interrupt Mode Operation 536EX Chipset Developer’s Manual Intel ConfidentialParallel Host Interface 16C450/16C550A UART