ISM can use an optional service partition on the server that you are managing. The service partition is a special disk partition on the system drive that contains a ROM-DOSoperating system and

DOS-based utilities, including the System Setup Utility, FRU/SDR Load Utility, and Remote Diagnostics. The server can be booted to the service partition, either locally or remotely, to provide access to the utilities.

For more information on Intel Server Management and the individual ISM applications, see the

ISM CD.

Security

Intrusion Switch Monitoring

To help prevent unauthorized entry or use of the server, Intel Server Management server management software monitors the chassis intrusion switch if one is installed. Opening an access cover will transmit an alarm signal to the server board, where BMC firmware and server management software process the signal. The system can be configured through ISM to respond to an intrusion a number of ways, including powering down or locking the keyboard.

Software Locks

The BIOS Setup and the System Setup Utility (SSU) provide a number of security features to prevent unauthorized or accidental access to the system. Once the security measures are enabled, you can access the system only after you enter the correct password(s). For example:

Enable the keyboard lockout timer so that the server requires a password to reactivate the keyboard and mouse after a specified time out period¾1 to 120 minutes.

Set and enable a supervisor password.

Set and enable a user password.

Set secure mode to prevent keyboard or mouse input and to prevent use of the front panel reset and power switches.

Activate a hot key combination to enter secure mode quickly.

Disable writing to the diskette drive when secure mode is set.

Disable access to the boot sector of the operating system hard disk drive.

Using Passwords

You can set either the user password, the supervisor password, or both passwords. If only the user password is set, you:

Must enter the user password to enter BIOS Setup or the SSU.

Must enter the user password to boot the server if Password on Boot is enabled in either the BIOS Setup or SSU.

Must enter the user password to exit secure mode.

Description

17

Image 17
Contents Intel Server Board SE7500WV2 Product Guide Page Contents Upgrading Configuration Software and UtilitiesEquipment Log and Power Consumption Worksheets Solving ProblemsTechnical Reference Regulatory and Integration InformationTables FiguresServer Board Features Server Board FeaturesDescription Server Board VersionsServer Board Connector and Component Locations Server Board Connector and Component LocationsBack Panel Connectors Back Panel ConnectorsMemory ProcessorPCI Riser Slots VideoATA-100 Controller Scsi ControllerNetwork Controller NIC Connector and Status LEDsKeyboard and Mouse RJ-45 Serial PortAbbreviation RJ-45 SignalRear Serial 2 Port Adapter Pin-out Baseboard Management Controller System ManagementPlatform Event Management Field Replaceable Units and Sensor Data RecordsSystem Event Log EMP and Serial Over LAN Emergency Management PortIntel Server Management Using Passwords Intrusion Switch MonitoringSecurity Software LocksSecure Mode Software Security Features Summary of Software Security FeaturesBoot without keyboard Rearrange the Standoffs Installation ProceduresInstalling the Server Board Install the Server BoardInstalling Processors Install the Processor Retention BracketsLower the locking bar completely Installing the Heat Sink Installing the Heat Sink Clip Installing Memory Connect Cables Connecting CablesInstalling a Service Partition on the Server Optional Installing Intel SMaRT Tool Installing your Operating SystemInstalling Intel Server Management Tools and Supplies Needed UpgradingInstalling DIMMs Adding or Replacing a Processor ProcessorsLower the locking bar completely Installing the Heat Sink Removing a Processor Replacing the Back up BatteryReplacing the Back up Battery Intel Server Board SE7500WV2 Product Guide Service Partition Optional Configuration Software and UtilitiesConfiguration Utilities System Software Update SequenceHot Keys Power-On Self-Test PostHot Keys To Do ThisTemporarily Changing the Boot Device Priority Bios SetupIf Bios Setup Is Inaccessible Configuring the Adaptec AIC-7899 Scsi Adapter When to Run the Adaptec SCSISelect UtilityRunning the Adaptec SCSISelect Utility Running the SCSISelect UtilityRunning the Promise FastBuild Utility When to Run the Promise FastBuild UtilityDirect Platform Control DPC Console Running the Promise FastBuild UtilityDPC Console Modes of Operation Creating SSU Diskettes Using the System Setup UtilityRunning the DPC Console Customizing the SSU Interface Running the SSUWorking with the SSU Interface Setting Passwords and Security Options Setting Boot Device PrioritySetting the Administrator Password Exiting the SSUViewing the System Event Log Setting the User PasswordSetting Security Options Viewing Sensor Data Records Viewing FRU InformationUpdating the Bios Updating System Firmware and BiosUpdating the Firmware Verifying the FirmwareSaving a Configuration Saving and Restoring the System ConfigurationRestoring a Configuration Setting Up Paging AlertsIntel Server Board SE7500WV2 Product Guide Setting Up LAN Alerts Managing the Server Remotely Setting Up Remote LAN AccessSetting Up Remote Modem or Serial Access Creating a Bootable Diskette Software UpdatesSoftware Update Package Recovering the BiosFRU/SDR Load Utility Description Firmware Update Utility DescriptionRunning the Firmware Update Utility Command Command Line FormatWhat You Need to Do How You Use the FRU/SDR Load UtilityPrompting for Product Level FRU Information Intel Server Board SE7500WV2 Product Guide Resetting the System Solving ProblemsChecklist Initial System StartupAfter the System Has Been Running Correctly Running New Application SoftwareMonitoring Post More Problem Solving ProceduresVerifying Proper Operation of Key System Lights Confirming Loading of the Operating SystemNo Characters Appear on Screen Specific Problems and Corrective ActionsPower Light Does Not Light Diskette Drive Activity Light Does Not Light Characters Are Distorted or IncorrectSystem Cooling Fans Do Not Rotate Properly Problems with Application Software Problems with NetworkBootable CD-ROM Is Not Detected CD-ROM Drive Activity Light Does Not LightCannot Connect to a Server Add-in adapter stopped working without apparent causeIntel Server Board SE7500WV2 Product Guide Technical Reference What it does at system resetServer Board Jumpers Jumper NameDiagnostic LED Decoder Post Diagnostic LEDsPost Codes Code0Fh 2Bh Off 2Dh 82h Off Standard Post Error Messages and Codes Post Error Codes and MessagesError Code Error Message119 11A 11B 11E 120 121 140 141 142 143 144 145 146 Extended Post Error Messages and Codes Bootblock Error Beep Codes Bios Recovery Beep CodesBios Recovery Beep Codes Bootblock Error Beep CodesIntel Server Board SE7500WV2 Product Guide Regulatory and Integration Information Product Safety ComplianceProduct Regulatory Compliance Product EMC ComplianceProduct Regulatory Compliance Markings FCC USA Electromagnetic Compatibility NoticesBsmi Taiwan Europe CE Declaration of ConformityEquipment Log Equipment Log and Power Consumption WorksheetsModel Number Serial Number Date InstalledManufacturer Name Worksheet, Calculating DC Power Usage Calculating Power ConsumptionPower Usage Worksheet Current UsageTotal Watts For each voltage level Worksheet, Total Combined Power Used by the SystemVoltage level and total current V X a = W Index Intel Server Board SE7500WV2 Product Guide