Intel SE7500WV2 manual 0Fh

Page 71

Table 13. Post Codes (continued)

Diagnostic LED Decoder

Post

G=Green, R=Red, A=Amber

Code

MSB

 

 

LSB

 

 

 

0Fh

G

G

G

G

 

 

 

 

 

Description

Write Command Byte 8042: The initialization after the keyboard controller BAT command test is done. The keyboard command byte will be written next.

10h

Off

Off Off R

Keyboard Init: The keyboard controller command byte is written. Next, issuing the pin 23 and 24 blocking and unblocking commands.

10h

11h

13h

19h

Off

Off

Off

G

Off Off R Off Off A

Off G A Off Off A

Disable and initialize 8259.

Detect Configuration Mode, such as CMOS clear.

Chipset Initialization before CMOS initialization.

Init System Timer: The 8254 timer test is over. Starting the memory refresh test next.

1Ah

23h

24h

25h

F2h

F5h

12h

12h

12h

27h

F4h

F6h

15h

15h

15h

26h

28h

29h

2Ah

G

Off

Off

Off

R

R

Off

Off

Off

Off

R

R

Off

Off

Off

Off

G

G

G

Off

G

R

 

 

 

Off

A

G

 

 

 

G

R

Off

 

 

 

G

R

G

 

 

 

R

A

R

 

 

 

A

R

A

 

 

 

Off

G

R

 

 

 

Off

G

R

 

 

 

Off

G

R

 

 

 

G

A

G

 

 

 

A

R

R

 

 

 

A

A

R

 

 

 

G

Off

A

 

 

 

G

Off

A

 

 

 

G

Off

A

 

 

 

G

A

Off

Off

R

Off

 

 

 

Off

R

G

 

 

 

Off

A

Off

 

 

 

Check Refresh Toggle: The memory refresh line is toggling. Checking the 15 second on/off time next.

Setup Interrupt Vectors: Reading the 8042 input port and disabling the MEGAKEY Green PC feature next. Making the BIOS code segment writable and performing any necessary configuration before initializing the interrupt vectors.

Before Vector: Configuration is required before interrupt vector initialization has completed. Interrupt vector initialization is about to begin.

Init interrupt Vectors: Interrupt vector initialization is done.

Initialize SMM handler. Initialize USB emulation.

Validate NVRAM areas. Restore from backup if corrupted.

Load defaults in CMOS RAM if bad checksum or CMOS clear jumper is detected.

Initializing APP CMOS RAM for appliance servers only.

Check point After CMOS Initialized.

Validate date and time in RTC.

Load Micro Code To All CPUs.

Scan SMBIOS GPNV areas.

8254 Timer Test on Channel 2.

Enable 8042.

Keyboard Reset.

Initialize LCD, if supported.

Set Video Mode: Initialization before setting the video mode is complete. Configuring the monochrome mode and color mode settings next.

Debugger Hook.

Init PCI devices and motherboard devices. Pass control to video BIOS. Start serial console redirection.

continued

Technical Reference

71

Image 71
Contents Intel Server Board SE7500WV2 Product Guide Page Contents Upgrading Configuration Software and UtilitiesRegulatory and Integration Information Solving ProblemsEquipment Log and Power Consumption Worksheets Technical ReferenceTables FiguresServer Board Versions Server Board FeaturesServer Board Features DescriptionServer Board Connector and Component Locations Server Board Connector and Component LocationsBack Panel Connectors Back Panel ConnectorsVideo ProcessorMemory PCI Riser SlotsATA-100 Controller Scsi ControllerRJ-45 Serial Port NIC Connector and Status LEDsNetwork Controller Keyboard and MouseAbbreviation RJ-45 SignalRear Serial 2 Port Adapter Pin-out Baseboard Management Controller System ManagementPlatform Event Management Field Replaceable Units and Sensor Data RecordsSystem Event Log EMP and Serial Over LAN Emergency Management PortIntel Server Management Software Locks Intrusion Switch MonitoringUsing Passwords SecuritySecure Mode Software Security Features Summary of Software Security FeaturesBoot without keyboard Rearrange the Standoffs Installation ProceduresInstalling the Server Board Install the Server BoardInstalling Processors Install the Processor Retention BracketsLower the locking bar completely Installing the Heat Sink Installing the Heat Sink Clip Installing Memory Connect Cables Connecting CablesInstalling a Service Partition on the Server Optional Installing Intel SMaRT Tool Installing your Operating SystemInstalling Intel Server Management Tools and Supplies Needed UpgradingInstalling DIMMs Adding or Replacing a Processor ProcessorsLower the locking bar completely Installing the Heat Sink Removing a Processor Replacing the Back up BatteryReplacing the Back up Battery Intel Server Board SE7500WV2 Product Guide System Software Update Sequence Configuration Software and UtilitiesService Partition Optional Configuration UtilitiesTo Do This Power-On Self-Test PostHot Keys Hot KeysTemporarily Changing the Boot Device Priority Bios SetupIf Bios Setup Is Inaccessible Running the SCSISelect Utility When to Run the Adaptec SCSISelect UtilityConfiguring the Adaptec AIC-7899 Scsi Adapter Running the Adaptec SCSISelect UtilityRunning the Promise FastBuild Utility When to Run the Promise FastBuild UtilityRunning the Promise FastBuild Utility Direct Platform Control DPC ConsoleDPC Console Modes of Operation Creating SSU Diskettes Using the System Setup UtilityRunning the DPC Console Customizing the SSU Interface Running the SSUWorking with the SSU Interface Exiting the SSU Setting Boot Device PrioritySetting Passwords and Security Options Setting the Administrator PasswordViewing the System Event Log Setting the User PasswordSetting Security Options Viewing Sensor Data Records Viewing FRU InformationVerifying the Firmware Updating System Firmware and BiosUpdating the Bios Updating the FirmwareSetting Up Paging Alerts Saving and Restoring the System ConfigurationSaving a Configuration Restoring a ConfigurationIntel Server Board SE7500WV2 Product Guide Setting Up LAN Alerts Managing the Server Remotely Setting Up Remote LAN AccessSetting Up Remote Modem or Serial Access Creating a Bootable Diskette Software UpdatesSoftware Update Package Recovering the BiosFRU/SDR Load Utility Description Firmware Update Utility DescriptionRunning the Firmware Update Utility How You Use the FRU/SDR Load Utility Command Line FormatCommand What You Need to DoPrompting for Product Level FRU Information Intel Server Board SE7500WV2 Product Guide Initial System Startup Solving ProblemsResetting the System ChecklistAfter the System Has Been Running Correctly Running New Application SoftwareConfirming Loading of the Operating System More Problem Solving ProceduresMonitoring Post Verifying Proper Operation of Key System LightsNo Characters Appear on Screen Specific Problems and Corrective ActionsPower Light Does Not Light Diskette Drive Activity Light Does Not Light Characters Are Distorted or IncorrectSystem Cooling Fans Do Not Rotate Properly CD-ROM Drive Activity Light Does Not Light Problems with NetworkProblems with Application Software Bootable CD-ROM Is Not DetectedCannot Connect to a Server Add-in adapter stopped working without apparent causeIntel Server Board SE7500WV2 Product Guide Jumper Name What it does at system resetTechnical Reference Server Board JumpersCode Diagnostic LEDsDiagnostic LED Decoder Post Post Codes0Fh 2Bh Off 2Dh 82h Off Error Message Post Error Codes and MessagesStandard Post Error Messages and Codes Error Code119 11A 11B 11E 120 121 140 141 142 143 144 145 146 Extended Post Error Messages and Codes Bootblock Error Beep Codes Bios Recovery Beep CodesBootblock Error Beep Codes Bios Recovery Beep CodesIntel Server Board SE7500WV2 Product Guide Product EMC Compliance Product Safety ComplianceRegulatory and Integration Information Product Regulatory ComplianceProduct Regulatory Compliance Markings FCC USA Electromagnetic Compatibility NoticesBsmi Taiwan Europe CE Declaration of ConformityEquipment Log Equipment Log and Power Consumption WorksheetsModel Number Serial Number Date InstalledManufacturer Name Current Usage Calculating Power ConsumptionWorksheet, Calculating DC Power Usage Power Usage WorksheetTotal Watts For each voltage level Worksheet, Total Combined Power Used by the SystemVoltage level and total current V X a = W Index Intel Server Board SE7500WV2 Product Guide