Intel SE7500WV2 manual Installing a Service Partition on the Server Optional

Page 29

Getting Started with Intel Server Management and Intel® SMaRT Tool (Optional)

Intel Server Management and the hard drive Service Partition provide real-time monitoring and alerting for your SE7500WV2 server hardware, emergency remote management, and remote server setup. Intel Server Management is implemented by installing it within client-server architecture.

The Service Partition provides you with the ability to remotely access a local partition on the server and to identify and diagnose server health issues. Remote access is provided through either a modem or network connection.

To get started with Intel Server Management, install the Service Partition first, then the system’s operating system, and finally Intel Server Management. The information here describes installation on a system running a Microsoft Windows operating system.

The Intel Server Maintenance and Reference Training (SMaRT) Tool is an interactive software tool providing support information to assist with the maintenance and repair of Intel-based server systems and accessories. SMaRT Tool features visual, step-by-step instructions for replacing parts; a complete Field Replaceable Unit (FRU) database containing part numbers and images; product spares lists, and worldwide Intel support information.

Intel Server Management provides an interface to the Intel® SMaRT Tool, combining remote error detection and alerting with interactive maintenance and repair assistance. When Intel Server Management detects a hardware error and a part needs replacing, SMaRT Tool can be launched directly from Intel Server Management to locate the correct part information and corresponding “How to Replace” steps required to quickly get the server back up and running.

To activate Intel Server Management’s interface with the Intel SMaRT Tool, both software programs need to be installed. You can install the software on a server or on a workstation used to manage the server. The information here describes installation on a system running a Microsoft Windows operating system. For other operating systems, see the Installation Guide & User Guide located in the ISM/DOCS folder on the Intel Server Management CD-ROM. SMaRT Tool and ISM Console may only be installed on a system running a Microsoft Windows operating system.

NOTE

Prior to installation, uninstall any previous version of Intel Server Management.

Installing a Service Partition on the Server (Optional)

The Service Partition provides advanced remote management and configuration functionality. Installing it on a server is optional.

1.Power-on the server, insert the Intel Server Management CD into the CD-ROM drive, and boot to the CD.

2.Select Utilities > Run Service Partition Administrator > Create Service Partition-first time.

3.Select an available hard drive. The server will reboot to the CD.

4.Select Format Service Partition and Install Software.

5.Exit the menu. Remove the CD and reboot to install the server operating system. After installing the operating system, proceed to Intel Server Management Installation.

Installation Procedures

29

Image 29
Contents Intel Server Board SE7500WV2 Product Guide Page Contents Upgrading Configuration Software and UtilitiesEquipment Log and Power Consumption Worksheets Solving ProblemsTechnical Reference Regulatory and Integration InformationTables FiguresServer Board Features Server Board FeaturesDescription Server Board VersionsServer Board Connector and Component Locations Server Board Connector and Component LocationsBack Panel Connectors Back Panel ConnectorsMemory ProcessorPCI Riser Slots VideoATA-100 Controller Scsi ControllerNetwork Controller NIC Connector and Status LEDsKeyboard and Mouse RJ-45 Serial PortAbbreviation RJ-45 SignalRear Serial 2 Port Adapter Pin-out Baseboard Management Controller System ManagementPlatform Event Management Field Replaceable Units and Sensor Data RecordsSystem Event Log EMP and Serial Over LAN Emergency Management PortIntel Server Management Using Passwords Intrusion Switch MonitoringSecurity Software LocksSecure Mode Software Security Features Summary of Software Security FeaturesBoot without keyboard Rearrange the Standoffs Installation ProceduresInstalling the Server Board Install the Server BoardInstalling Processors Install the Processor Retention BracketsLower the locking bar completely Installing the Heat Sink Installing the Heat Sink Clip Installing Memory Connect Cables Connecting CablesInstalling a Service Partition on the Server Optional Installing Intel SMaRT Tool Installing your Operating SystemInstalling Intel Server Management Tools and Supplies Needed UpgradingInstalling DIMMs Adding or Replacing a Processor ProcessorsLower the locking bar completely Installing the Heat Sink Removing a Processor Replacing the Back up BatteryReplacing the Back up Battery Intel Server Board SE7500WV2 Product Guide Service Partition Optional Configuration Software and UtilitiesConfiguration Utilities System Software Update SequenceHot Keys Power-On Self-Test PostHot Keys To Do ThisTemporarily Changing the Boot Device Priority Bios SetupIf Bios Setup Is Inaccessible Configuring the Adaptec AIC-7899 Scsi Adapter When to Run the Adaptec SCSISelect UtilityRunning the Adaptec SCSISelect Utility Running the SCSISelect UtilityRunning the Promise FastBuild Utility When to Run the Promise FastBuild UtilityDirect Platform Control DPC Console Running the Promise FastBuild UtilityDPC Console Modes of Operation Creating SSU Diskettes Using the System Setup UtilityRunning the DPC Console Customizing the SSU Interface Running the SSUWorking with the SSU Interface Setting Passwords and Security Options Setting Boot Device PrioritySetting the Administrator Password Exiting the SSUViewing the System Event Log Setting the User PasswordSetting Security Options Viewing Sensor Data Records Viewing FRU InformationUpdating the Bios Updating System Firmware and BiosUpdating the Firmware Verifying the FirmwareSaving a Configuration Saving and Restoring the System ConfigurationRestoring a Configuration Setting Up Paging AlertsIntel Server Board SE7500WV2 Product Guide Setting Up LAN Alerts Managing the Server Remotely Setting Up Remote LAN AccessSetting Up Remote Modem or Serial Access Creating a Bootable Diskette Software UpdatesSoftware Update Package Recovering the BiosFRU/SDR Load Utility Description Firmware Update Utility DescriptionRunning the Firmware Update Utility Command Command Line FormatWhat You Need to Do How You Use the FRU/SDR Load UtilityPrompting for Product Level FRU Information Intel Server Board SE7500WV2 Product Guide Resetting the System Solving ProblemsChecklist Initial System StartupAfter the System Has Been Running Correctly Running New Application SoftwareMonitoring Post More Problem Solving ProceduresVerifying Proper Operation of Key System Lights Confirming Loading of the Operating SystemNo Characters Appear on Screen Specific Problems and Corrective ActionsPower Light Does Not Light Diskette Drive Activity Light Does Not Light Characters Are Distorted or IncorrectSystem Cooling Fans Do Not Rotate Properly Problems with Application Software Problems with NetworkBootable CD-ROM Is Not Detected CD-ROM Drive Activity Light Does Not LightCannot Connect to a Server Add-in adapter stopped working without apparent causeIntel Server Board SE7500WV2 Product Guide Technical Reference What it does at system resetServer Board Jumpers Jumper NameDiagnostic LED Decoder Post Diagnostic LEDsPost Codes Code0Fh 2Bh Off 2Dh 82h Off Standard Post Error Messages and Codes Post Error Codes and MessagesError Code Error Message119 11A 11B 11E 120 121 140 141 142 143 144 145 146 Extended Post Error Messages and Codes Bootblock Error Beep Codes Bios Recovery Beep CodesBios Recovery Beep Codes Bootblock Error Beep CodesIntel Server Board SE7500WV2 Product Guide Regulatory and Integration Information Product Safety ComplianceProduct Regulatory Compliance Product EMC ComplianceProduct Regulatory Compliance Markings FCC USA Electromagnetic Compatibility NoticesBsmi Taiwan Europe CE Declaration of ConformityEquipment Log Equipment Log and Power Consumption WorksheetsModel Number Serial Number Date InstalledManufacturer Name Worksheet, Calculating DC Power Usage Calculating Power ConsumptionPower Usage Worksheet Current UsageTotal Watts For each voltage level Worksheet, Total Combined Power Used by the SystemVoltage level and total current V X a = W Index Intel Server Board SE7500WV2 Product Guide