Intel SE7500WV2 manual Diagnostic LEDs, Post Codes, Diagnostic LED Decoder Post

Page 70

Diagnostic LEDs

To help diagnose POST failures, a set of four bi-color diagnostic LEDs is located on the back edge of the baseboard. Each of the four LEDs can have one of four states: Off, Green, Red, or Amber.

The LED diagnostics feature consists of a hardware decoder and four dual color LEDs. During POST, the LEDs will display all normal Port80 codes representing the progress of the BIOS POST. Each postcode will be represented by a combination of colors from the 4 LEDs. The LEDs are in pairs of green and red. The post codes are broken into two nibbles, an upper and a lower nibble. Each bit in the upper nibble is represented by a red LED and each bit in the lower nibble is represented by a green LED. If both bits are set in the upper and lower nibble then both red and green LEDs are lit, resulting in an amber color. Likewise, if both bits are clear then the red and green LEDs are off.

During the POST process, each light sequence represents a specific Port-80 POST code. If a system should hang during POST, the Diagnostic LEDs will present the last test executed before the hang. When reading the lights, the LEDs should be observed from the back of the system. The most significant bit (MSB) is the first LED on the left, and the least significant bit (LSB) is the last LED on the right.

NOTE

When comparing a diagnostic LED color string from the baseboard to those listed in the diagnostic LED decoder in the following tables, the LEDs on the baseboard should be referenced when viewed by looking into the system from the back. Reading the LEDs from left to right, the Hi bit is located on the left.

Table 13. Post Codes

Diagnostic LED Decoder

Post

G=Green, R=Red, A=Amber

Code

MSB

LSB

 

Description

07h

08h

08h

07h

07h

0Bh

0Ch

Off

G

G

Off

Off

G

G

G

G

G

 

 

 

Off

Off

Off

Off

Off

Off

 

 

 

G

G

G

 

 

 

G

G

G

 

 

 

Off

G

G

 

 

 

G

Off

Off

 

 

 

Uncompress various BIOS Modules.

Verify password Checksum.

Verify CMOS Checksum.

Read Microcode updates from BIOS ROM.

Initializing the processors. Set up processor registers. Select least featured processor as the BSP.

Hook before the keyboard BAT command is issued.

Keyboard Controller Test: The keyboard controller input buffer is free. Next, issuing the BAT command to the keyboard controller.

0Eh

G

G

G

Off

 

 

 

 

 

Init after Keyboard Test: The keyboard controller BAT command result has been verified. Next, performing any necessary initialization after the keyboard controller BAT command test.

continued

70

Intel Server Board SE7500WV2 Product Guide

Image 70
Contents Intel Server Board SE7500WV2 Product Guide Page Contents Configuration Software and Utilities UpgradingTechnical Reference Solving ProblemsEquipment Log and Power Consumption Worksheets Regulatory and Integration InformationFigures TablesDescription Server Board FeaturesServer Board Features Server Board VersionsServer Board Connector and Component Locations Server Board Connector and Component LocationsBack Panel Connectors Back Panel ConnectorsPCI Riser Slots ProcessorMemory VideoScsi Controller ATA-100 ControllerKeyboard and Mouse NIC Connector and Status LEDsNetwork Controller RJ-45 Serial PortRear Serial 2 Port Adapter Pin-out RJ-45 SignalAbbreviation System Management Baseboard Management ControllerSystem Event Log Field Replaceable Units and Sensor Data RecordsPlatform Event Management Intel Server Management Emergency Management PortEMP and Serial Over LAN Security Intrusion Switch MonitoringUsing Passwords Software LocksSecure Mode Summary of Software Security Features Software Security FeaturesBoot without keyboard Installation Procedures Rearrange the StandoffsInstall the Server Board Installing the Server BoardInstall the Processor Retention Brackets Installing ProcessorsLower the locking bar completely Installing the Heat Sink Installing the Heat Sink Clip Installing Memory Connecting Cables Connect CablesInstalling a Service Partition on the Server Optional Installing Intel Server Management Installing your Operating SystemInstalling Intel SMaRT Tool Upgrading Tools and Supplies NeededInstalling DIMMs Processors Adding or Replacing a ProcessorLower the locking bar completely Installing the Heat Sink Replacing the Back up Battery Removing a ProcessorReplacing the Back up Battery Intel Server Board SE7500WV2 Product Guide Configuration Utilities Configuration Software and UtilitiesService Partition Optional System Software Update SequenceHot Keys Power-On Self-Test PostHot Keys To Do ThisIf Bios Setup Is Inaccessible Bios SetupTemporarily Changing the Boot Device Priority Running the Adaptec SCSISelect Utility When to Run the Adaptec SCSISelect UtilityConfiguring the Adaptec AIC-7899 Scsi Adapter Running the SCSISelect UtilityDirect Platform Control DPC Console When to Run the Promise FastBuild UtilityRunning the Promise FastBuild Utility Running the Promise FastBuild UtilityDPC Console Modes of Operation Running the DPC Console Using the System Setup UtilityCreating SSU Diskettes Working with the SSU Interface Running the SSUCustomizing the SSU Interface Setting the Administrator Password Setting Boot Device PrioritySetting Passwords and Security Options Exiting the SSUSetting Security Options Setting the User PasswordViewing the System Event Log Viewing FRU Information Viewing Sensor Data RecordsUpdating the Firmware Updating System Firmware and BiosUpdating the Bios Verifying the FirmwareRestoring a Configuration Saving and Restoring the System ConfigurationSaving a Configuration Setting Up Paging AlertsIntel Server Board SE7500WV2 Product Guide Setting Up LAN Alerts Setting Up Remote Modem or Serial Access Setting Up Remote LAN AccessManaging the Server Remotely Software Updates Creating a Bootable DisketteRecovering the Bios Software Update PackageRunning the Firmware Update Utility Firmware Update Utility DescriptionFRU/SDR Load Utility Description What You Need to Do Command Line FormatCommand How You Use the FRU/SDR Load UtilityPrompting for Product Level FRU Information Intel Server Board SE7500WV2 Product Guide Checklist Solving ProblemsResetting the System Initial System StartupRunning New Application Software After the System Has Been Running CorrectlyVerifying Proper Operation of Key System Lights More Problem Solving ProceduresMonitoring Post Confirming Loading of the Operating SystemPower Light Does Not Light Specific Problems and Corrective ActionsNo Characters Appear on Screen System Cooling Fans Do Not Rotate Properly Characters Are Distorted or IncorrectDiskette Drive Activity Light Does Not Light Bootable CD-ROM Is Not Detected Problems with NetworkProblems with Application Software CD-ROM Drive Activity Light Does Not LightAdd-in adapter stopped working without apparent cause Cannot Connect to a ServerIntel Server Board SE7500WV2 Product Guide Server Board Jumpers What it does at system resetTechnical Reference Jumper NamePost Codes Diagnostic LEDsDiagnostic LED Decoder Post Code0Fh 2Bh Off 2Dh 82h Off Error Code Post Error Codes and MessagesStandard Post Error Messages and Codes Error Message119 11A 11B 11E 120 121 140 141 142 143 144 145 146 Extended Post Error Messages and Codes Bios Recovery Beep Codes Bios Recovery Beep CodesBootblock Error Beep Codes Bootblock Error Beep CodesIntel Server Board SE7500WV2 Product Guide Product Regulatory Compliance Product Safety ComplianceRegulatory and Integration Information Product EMC ComplianceProduct Regulatory Compliance Markings Electromagnetic Compatibility Notices FCC USAEurope CE Declaration of Conformity Bsmi TaiwanEquipment Log and Power Consumption Worksheets Equipment LogManufacturer Name Serial Number Date InstalledModel Number Power Usage Worksheet Calculating Power ConsumptionWorksheet, Calculating DC Power Usage Current UsageVoltage level and total current V X a = W Worksheet, Total Combined Power Used by the SystemTotal Watts For each voltage level Index Intel Server Board SE7500WV2 Product Guide