Kodak i30 / i40 manual Fixed thresholding ATP disabled

Page 60

Binarization the following descriptions are for binary images only.

The following binarization options work on grayscale scanned images and outputs a bi-tonal electronic image. Their strength lies in the ability to separate the foreground information from the background information even when the background color or shading varies, and the foreground information varies in color quality and darkness. Different types of documents may be scanned using the same image processing parameters and results in excellent scanned images.

Available binarization options are:

iThresholding: selecting iThresholding allows the scanner to dynamically evaluate each document to determine the optimal threshold value to produce the highest quality image. This allows scanning of mixed document sets with varying quality (i.e., faint text, shaded backgrounds, color backgrounds) to be scanned using a single setting thus reducing the need for document sorting.

When using iThresholding, only Contrast may be adjusted.

Fixed Processing (FP): used for black-and-white and other high contrast documents. A single level is set to determine the black-and- white transition. The threshold is programmable over the entire density range. Fixed thresholding sets the contrast to 0. If Fixed Processing is selected, Contrast is not available.

Adaptive Thresholding (ATP): the Adaptive Threshold Processor separates the foreground information in an image (i.e., text, graphics, lines, etc.) from the background information (i.e., white or non-white paper background).

When using Adaptive Thresholding, Threshold and Contrast may be adjusted. Contrast values may range from 1 to 100. A Contrast value of 100 is considered fully adaptive thresholding.

Fixed thresholding ATP disabled

ATP enabled

Dithering a method used to simulate gray levels. When selected, the Dithering options are available.

64-Level Bayer Dither, 64-Level 45 Degree Clustered Dot Screen and 64-Level Dispersed Dot Screen: these represent alternative screening options to emulate gray.

A-61512 May 2006

57

Image 60
Contents User’s Guide Contents Maintenance Introduction Scanner features Safety information Safety and regulatoryAgency approvals EMC statements United StatesJapan Power system Acoustic emissionConnection European UnionGetting Started What’s in the box System requirementsAttaching the input tray Installing the Kodak Driver Software Select Install Scanner SoftwareAttaching the output tray and special document feeder Page Page Select USB Test United States Canada China power cord Connecting the USB CablePage Installing application SoftwareScanner components Front viewInside view Back viewAdjusting the input and output trays Turning the scanner on and offStart and stop scanning Front-feed minimum/center alignment 6.35 x 5.08 cm 2.5 x 2.0Verifying your scanner installation Page Page Viewing test images Application softwareConfiguring functions ManagerPage Installing Configuring ReadirisSelect Scanner Model Page Assigning function NumbersUsing function numbers Scanning your documents Scanning documents using the special document feeder Overview Common termsBi-tonal or Binary black-and-white Making camera SelectionsExample 1 scanning a two-sided color document both sides ColorStarting the Scan Validation Tool Scan Validation Tool dialog box Using the Twain Datasource Kodak Scanner Properties dialog boxButtons on the Kodak Scanner Properties dialog box Imaging tab Page Disabled No Noise Filter Used Dpi 80 Threshold 200 dpi Contrast 100 Page Page Paper tab Cropping valuesPage 61512 May Page Dropout tab Better, Best, SuperiorRemove Red, Remove Green, Remove Blue Multifeed tab Options tab Setup tab Tool, via the Twain DatasourceInfo tab Using the Isis Driver Scanner Settings dialogSettings dialog box BoxCamera Settings area Page Page Fixed thresholding ATP disabled Dpi 80 Threshold 20 Contrast Dpi 80 Threshold 100 Contrast More Scanner Settings dialog box Image Control options Black on White polarity White on Black polarity Color Dropout options Scanner Control Dialog boxMulti-Feed Detection OptionsDefining the Scan area Area Maintenance Cleaning the rollers Cleaning the feed moduleCleaning the calibration area Replacing the feed ModuleSupplies and consumables Indicator lights and error codes Clearing a document jamProblem solving Problem Possible Solution61512 May Scanner not working Page Page Testing for a USB Connection\program files\Kodak\Document Imaging\usbtst.exe Solutions Your operating system only supports USBYou do not need to install any additional USB cards USB will not workAppendix a Specifications Eastman Kodak Company