Using the TWAIN Datasource

Kodak Scanner Properties dialog box

Buttons on the Kodak Scanner Properties dialog box

The TWAIN Datasource is a piece of software that communicates with your scanner. It is provided by Kodak with the i30 and i40 Scanners. Many scanning applications support the TWAIN standard and this datasource can be used to interface with these applications.

This section provides descriptions of the scanner features using options on the TWAIN tabs and how to set these options. If you are using the TWAIN Datasource, follow the procedures in this section to set up your scanner. If you are using the ISIS Driver, see the section entitled, “Using the ISIS Driver” later in this chapter.

For the purpose of this manual, all displayed dialog boxes assume the features available on the Kodak i40 Scanner (duplex scanner). If you have a Kodak i30 Scanner (simplex scanner) all options are limited to simplex scanning only.

The Kodak Scanner Properties dialog box allows you to review and configure the scanner’s settings. It consists of several tabbed windows each of which will be described within this chapter.

Click on each tab to set all the desired values. You do not have to click OK until you have made all selections on all of the tabs.

Following are descriptions of the buttons located at the bottom of the dialog box.

Defaults when you select Defaults, the message Reset all values to factory defaults? will be shown. Clicking Yes on this message will reset all values on all tabs to the factory default settings.

Copy copies the settings of the front camera to the rear camera for the selected camera (bi-tonal, color or grayscale). For example, if you have Front Bi-tonalhighlighted, these values will be copied to the Rear Bi-tonal camera. If you have Front Color highlighted, these values will be copied to the Rear Color camera. This option is only available for the Kodak i40 Scanner.

OK saves the values set on all tabs.

Cancel closes the dialog box without saving any changes.

36

A-61512 May 2006

Image 39
Contents User’s Guide Contents Maintenance Introduction Scanner features Safety information Safety and regulatoryAgency approvals EMC statements United StatesJapan European Union Power systemAcoustic emission ConnectionWhat’s in the box System requirements Getting StartedAttaching the input tray Installing the Kodak Driver Software Select Install Scanner SoftwareAttaching the output tray and special document feeder Page Page Select USB Test United States Canada China power cord Cable Connecting the USBPage Software Installing applicationFront view Scanner componentsBack view Inside viewTurning the scanner on and off Adjusting the input and output traysFront-feed minimum/center alignment 6.35 x 5.08 cm 2.5 x 2.0 Start and stop scanningVerifying your scanner installation Page Page Application software Viewing test imagesManager Configuring functionsPage Configuring Readiris InstallingSelect Scanner Model Page Numbers Assigning functionUsing function numbers Scanning your documents Scanning documents using the special document feeder Overview Common termsBi-tonal or Binary black-and-white Color Making cameraSelections Example 1 scanning a two-sided color document both sidesStarting the Scan Validation Tool Scan Validation Tool dialog box Using the Twain Datasource Kodak Scanner Properties dialog boxButtons on the Kodak Scanner Properties dialog box Imaging tab Page Disabled No Noise Filter Used Dpi 80 Threshold 200 dpi Contrast 100 Page Page Cropping values Paper tabPage 61512 May Page Dropout tab Better, Best, SuperiorRemove Red, Remove Green, Remove Blue Multifeed tab Options tab Tool, via the Twain Datasource Setup tabInfo tab Box Using the Isis DriverScanner Settings dialog Settings dialog boxCamera Settings area Page Page Fixed thresholding ATP disabled Dpi 80 Threshold 20 Contrast Dpi 80 Threshold 100 Contrast More Scanner Settings dialog box Image Control options Black on White polarity White on Black polarity Color Dropout options Options Scanner ControlDialog box Multi-Feed DetectionDefining the Scan area Area Maintenance Cleaning the feed module Cleaning the rollersCleaning the calibration area Module Replacing the feedSupplies and consumables Clearing a document jam Indicator lights and error codesProblem Possible Solution Problem solving61512 May Scanner not working Page Page Testing for a USB Connection\program files\Kodak\Document Imaging\usbtst.exe Your operating system only supports USB SolutionsUSB will not work You do not need to install any additional USB cardsAppendix a Specifications Eastman Kodak Company