Options

3.0OPTIONS

3.1Remote Alarm Unit

A remote alarm panel is available for displaying important individual UPS messages. The length of the connection cable must not exceed 1000ft.

3.2MopUPS Shutdown and Monitoring Software

The MopUPS Professional software package provides safe system shutdown and power management. With advanced features such as network shutdown, scheduled shutdown and restart, event messaging, event logging, data logging, real time viewing, UPS diagnostics and remote access, MopUPS has everything necessary for preserving data and maximizing system uptime.

The software features:

1.Remote management

Site power and UPS status information can be accessed securely from any computer on your IP- based network. View event history and voltage logs for trend analysis. View UPS system status in real time for situational decision support. Access is based on User Authentication with 128-bit, MD5 encryption.

2.Remote messaging

Keeps you informed anywhere -- fault and recovery messages are sent via SNMP Trap or e-mail. Body of e-mail will include URL for quick link back to UPS Web page. Many pager systems will forward e-mail to your wireless pager - so you can be informed anywhere.

3.Safe system shutdown

Preserves data integrity and minimizes recovery delays with automated system shutdown. MopUPS monitors the UPS for power failure, low battery, or other events that jeopardize com- puter power -- and initiates controlled system shutdown.

While it is always possible to use a serial connection, Emerson recommends employing a ManageUPS network SNMP adapter for communication between MopUPS Professional and Liebert NX so that multiple Server Systems can communicate with the UPS via Ethernet.

With Liebert NX in redundant parallel configuration, MopUPS P/R Edition monitors all the connected Liebert NX units simultaneously. It acquires load data, estimated capacities, and other measurements from individual modules, and groups them together according to whether the system is serial or parallel-redundant and whether it is centralized or parallel-distributed (with or without redundancy). This special edition of MopUPS can analyze module-specific conditions and report situations that may affect redundancy or power margin.

ManageUPS Net Adapter is required when using MopUPS P/R Edition. For more details, see http://connectivity.Emersonpower.com/

27

Liebert®NX

Image 33
Contents Liebert NX Product Warranty Registration Table of Contents Maintenance SpecificationsOptions Figures Page Important Safety Instructions Battery Cabinet Precautions General Description Typical single module UPS system one-line diagramBypass Mode Normal ModeBattery Mode Maintenance BypassOptions Main component locations-225 to 300kVA Liebert NX FeaturesFront Doors Removed Main display screen, typical Touchscreen Navigation Main Display ScreenSystem Status Status Rectifier Bypass Inverter Chg/Boost Battery LoadEvents Log Menu Measures MenuBattery Menu Battery StatusBattery Test Battery parameters Battery MeasuresLife menu Life MenuAnimated One Line Mimic Settings MenuRectifier Functional Block About MenuLoad on bypass, UPS available Load on BypassOff DC Source Input Power Failure-Load on DC SourceManual Operations-All Systems Remote Emergency Power OffStartup-Single Module System Startup-1+N System Transfer Procedure Retransfer ProcedureLoad Transfer and Retransfer-Single Module System 6 1+N System Transfer load from UPS to Bypass 7 1+N System Transfer load from Bypass to UPS Shut Down-Single Module UPS System9 1+N System Shutdown Load Transfer-1+N System Add a UPS to the System Collective Load Transfer-1+N System Remove a UPS from System CollectiveAutomatic Operations Overloads Without TransferCurrent-versus-time curves of overload capacity Automatic Transfers to Bypass Overload Condition Automatic Transfers to Bypass, UPS System FaultsAutomatic Retransfers to UPS MopUPS Shutdown and Monitoring Software Remote Alarm UnitManage UPS Adapter ConnectivityConnectivity combinations Available Selectable Output Contacts Available Selectable Input ContactsSafety Precautions Maintenance Agreements The Signature Program Liebert ServicesProfessional Startup TrainingRoutine Maintenance Record LogAir Filters UPS component service life Battery MaintenanceLimited Life Components Component Expected Life ReplaceBattery Safety Precautions Battery voltage, nominal and float Matching Battery Cabinets-OptionalBattery Voltage, VDC Number of Cells Nominal Float 240 480 527Battery Mfr Battery Model # In-lb N-m Battery retorque valuesOther DC Sources Retorque ValueUpstream Feeder Circuit Breaker Setting Inspections Reporting a ProblemDetecting Trouble Items to check includeEnvironmental specifications Battery OperationDC Sources Other DC SourcesPhysical specifications Electrical specificationsSpecifications LiebertNX Page Is t Ne tTwor k Care