MatrixPRO Remote Commands
il^aojm
•Description: Places unit into loader mode. This mode is used to perform field upgrades
•Parameters: None.
S Example: LOADRMP (Puts unit into loader mode.)
l_ikh=çìí=Ääåâ
•
•
Description: Updates output blanking status
Parameters:
out Output number; [1 - 16]
blnk Blanking status; [01], DisableEnable
• Query: OBLNK? out Returns the selected output blanking status in the format:
=blnk
S Example: OBLNK 2 1 (Blank output 2.)
lpq^q
•
Description: Displays output information (i.e., which input video/audio # routed, audio level, etc). This command is used in the MatrixPRO Remote Control Panel to return the result.
•Parameters: out
Note
SExamples:
Output number; [1 - 16]
This parameter is optional, if no parameter is specified, all output information (i.e.,
OSTAT 1 (Displays output status for output 1.)
OSTAT (Displays output status for all outputs.)
mopq=åìã
•Description: Saves current front panel configuration/routing to a Preset location
•Parameters:
out Preset number to save to; [1 - 16]
S Example: PRST 1 (Saves configuration to preset location 1.)