IBM 8490, 8485 manual Features and specifications

Page 19

Features and specifications

The following information is a summary of the features and specifications of the server. Depending on the server model, some features might not be available, or some specifications might not apply.

Table 1. Features and specifications

Microprocessor:

vIntel® Pentium® 4 Processor

v1 MB or 2 MB Level-2 or Level-3 cache

v800 MHz front-side bus (FSB)

Memory:

vMinimum: 512 MB

vMaximum: 8 GB

vTypes: PC2-4200 double-data-rate 2 (DDR2)

vConnectors: four dual inline memory module (DIMM) connectors, two-way interleaved

Drives (depending on the model):

vDiskette (optional): 1.44 MB (two modes)

vHard disk drive: SAS or SATA

vOne of the following IDE drives:

CD-ROM

CD-RW (optional)

DVD-ROM (optional)

DVD-ROM/CD-RW (optional)

Expansion bays (depending on the model):

vTwo 5.25-in. bays (one CD drive installed)

vOne 3.5-in. removable-media drive bay

vFour 3.5-in. hard disk drive bays with one of the following bays:

Open hot-swap bays

Simple-swap bays with one hard disk drive installed

Non-hot-swap bays with one hard disk drive installed

PCI expansion slots (depending on the model):

vFour PCI expansion slots

One PCI Express x8 slot

One PCI Express x1 slot

Two PCI 32-bit/33 MHz slots

vSix PCI expansion slots (models with the PCI-X expansion card)

One PCI Express x8 slot

One PCI Express x1 slot

Two PCI 32-bit/33 MHz slots

Two PCI-X 64-bit/100 MHz slots

vOne connector on PCI-X expansion card for the mini-PCI-X Serial Attached SCSI (SAS) adapter

Fans:

Two or three speed-controlled fans

Power supply:

One of the following power supplies:

vTwo redundant 430 watt (90-240 V ac)

vOne nonredundant 400 watt (90-240 V ac)

Size:

vHeight: 438 mm (17.25 in.)

vDepth: 540 mm (21.25 in.)

vWidth: 216 mm (8.5 in.)

vWeight: 16.3 kg (36 lb) to 20.8 kg (45.8 lb) depending upon configuration

Integrated functions:

vMini baseboard management controller (mini-BMC)

vBroadcom 5721 10/100/1000 Ethernet controller on the system board with RJ-45 Ethernet port

vTwo serial ports

vOne parallel port

vFour-port Serial ATA controller

vOne internal SAS port (mini-PCI slot)

vIntegrated RAID capability (HostRAID)

vFour Universal Serial Bus (USB) v2.0 ports (two on front and two on rear)

vKeyboard port

vMouse port

vATA-100 single-channel IDE controller (bus mastering)

vATI ES1000 video controller

Compatible with SVGA and VGA

16 MB SDRAM video memory

Diagnostic LEDs:

vFans

vMemory

Acoustical noise emissions:

vSound power, idling: 5.0 bel

vSound power, operating: 5.5 bel

Environment:

vAir temperature:

Server on: 10° to 35°C (50° to 95°F)

Altitude: 0 to 914 m (2998.0 ft)

Server off: -40° to 60°C (-40° to 140°F)

Altitude: 0 to 2133 m (7000.0 ft)

vHumidity (operating and storage): 8% to 80%

Heat output:

Approximate heat output in British thermal units (Btu) per hour:

vMinimum configuration: 630 Btu per hour (185 watts)

vMaximum configuration: 1784 Btu per hour (523 watts)

Electrical input:

vSine-wave input (50 or 60 Hz) required

vInput voltage and frequency ranges automatically selected

vInput voltage low range:

Minimum: 100 V ac

Maximum: 127 V ac

vInput voltage high range:

Minimum: 200 V ac

Maximum: 240 V ac

vInput kilovolt-amperes (kVA) approximately:

Minimum: 0.20 kVA (all models)

Maximum: 0.55 kVA

Notes:

1.Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.

2.These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below which a large number of computers will operate.

Chapter 1. Introduction 5

Image 19
Contents Installation Guide Eserver/support/xseries Index.html Serverproven/compat/usInstallation Guide Page Contents Appendix A. Getting help and technical assistance Safety Vi xSeries 206m Types 8485 and 8490 Installation Guide To Connect To Disconnect Do not Safety Statement Safety Xii xSeries 206m Types 8485 and 8490 Installation Guide Introduction Model number and serial number Using the Documentation Browser XSeries 206m Types 8485 and 8490 Installation Guide Features and specifications Features and specificationsDimm Major components of the xSeries 206m Types 8485Installation guidelines Installing optionsSystem reliability guidelines Working inside the server with the power onHandling static-sensitive devices Removing the side cover Removing the two-piece bezel XSeries 206m Types 8485 and 8490 Installation Guide Installing a memory module Dimm Number of DIMMs Connector sequence Installing a drive Installing a drive in bay 2 or XSeries 206m Types 8485 and 8490 Installation Guide Installing a hot-swap hard disk drive in bay 4, 5, 6, or XSeries 206m Types 8485 and 8490 Installation Guide IDs for hot-swap hard disk drives XSeries 206m Types 8485 and 8490 Installation Guide Installing options Power and signal cables for internal drives Installing an adapter To install an adapter, complete the following steps Adapter guide Reinstalling the two-piece bezel Completing the installationInstalling options Reinstalling the side cover Connecting the cables Updating the server configuration Front view Server controls, LEDs, and powerOptional Diskette-eject button USB connectorsCD-eject or DVD-eject button CD or DVD drive activity LEDRear view Ethernet transmit/receive activity LED Server power featuresTurning on the server Turning off the serverServer controls, LEDs, and power XSeries 206m Types 8485 and 8490 Installation Guide Using the ServerGuide Setup and Installation CD Configuring the serverUsing the Configuration/Setup Utility program Using the Adaptec HostRAID configuration programs Select Array Configuration Utility Select Create Array Enabling the Serial ATA HostRAID featureConfiguring the server Enabling the SAS/SATA HostRAID feature Using the SAS/SATA Utility program for SAS/SATA HostRAIDConfiguring the controller Using ServeRAID ManagerClick Express configuration Viewing the configurationClick Custom configuration Configuring the Ethernet controller Using the Boot Menu programXSeries 206m Types 8485 and 8490 Installation Guide Diagnostic tools overview Solving problemsPost beep codes One long beep and two short beeps Post error codesOther beep codes Default Settings, and save Determination and Service Abbreviated list of Post error codes Update the mini-BMC firmware Components, depending on Make sure that the settings for Abbreviated list of Post error codes Abbreviated list of Post error codes Hard disk drive cable Only Replace Abbreviated list of Post error codes Problem Determination Troubleshooting tables ServerGuide problemsCD or DVD drive problems General problems Diskette drive problemsHard disk drive problems Intermittent problems Keyboard, mouse, or pointing-device problems Memory problems Monitor problems Microprocessor problemsOn the IBM xSeries Documentation CD Service Guide on the IBM xSeries Documentation CD Optional-device problems Power problems See the User’s Guide on the IBM xSeries Documentation CD Serial port problemsUniversal Serial Bus device problems Software problemsSystem-board LEDs Appendix A. Getting help and technical assistance Using the documentationBefore you call Getting help and information from the World Wide Web Software service and support Hardware service and supportEdition notice Appendix B. NoticesImportant notes TrademarksProduct recycling and disposal Battery return program European Union EMC Directive conformance statement Electronic emission notices Class aFederal Communications Commission FCC statement Industry Canada Class a emission compliance statementXSeries 206m Types 8485 and 8490 Installation Guide Industry Canada Class B emission compliance statement Electronic emission notices Class BAvis de conformité à la réglementation d’Industrie Canada European Union EMC Directive conformance statement Macedonia former Yugoslav Republic of, Madagascar, Mali XSeries 206m Types 8485 and 8490 Installation Guide SAS/SATA IndexDrive simple-swap Drives Installing Size Software problems Problems XSeries 206m Types 8485 and 8490 Installation Guide Page Part Number 40K2367