Table 2. Abbreviated list of POST error codes (continued)
vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Error code | Description | Action | |
|
|
|
|
I9990650 | AC power has been restored. | 1. | Reseat the power cords. |
|
| ||
|
| 2. | Check for interruption of the |
|
|
| external power. |
|
| 3. | Replace the power cords. |
|
|
|
|
ServerGuide problems
The following table lists problem symptoms and suggested solutions.
Table 3. ServerGuide Setup and Installation CD
Symptom | Action |
|
|
The ServerGuide Setup | v Make sure that the server supports the ServerGuide program and has a startable |
and Installation CD will | (bootable) CD or DVD drive. |
not start. | v If the startup (boot) sequence settings have been changed, make sure that the CD or |
| DVD drive is first in the startup sequence. |
| v If more than one CD or DVD drive is installed, make sure that only one drive is set as |
| the primary drive. Start the CD from the primary drive. |
|
|
ServeRAID program | v Make sure that there are no duplicate IRQ assignments. |
cannot view all installed | v Make sure that the hard disk drive is connected correctly. |
drives or the operating |
|
system cannot be |
|
installed. |
|
|
|
The | Make more space available on the hard disk. |
installation program |
|
continuously loops. |
|
|
|
The ServerGuide | Make sure that the |
program will not start the | the ServerGuide Setup and Installation CD label for a list of supported |
versions. | |
|
|
The operating system | Make sure that the |
cannot be installed; the | system is supported, no logical drive is defined (RAID servers). Run the ServerGuide |
option is not available. | program and make sure that setup is complete. |
|
|
Troubleshooting tables
Use the following tables to find solutions to problems that have identifiable symptoms. See the Problem Determination and Service Guide on the IBM xSeries Documentation CD for more detailed troubleshooting information. If you cannot find the problem in these tables, run the diagnostic programs (see “Running the diagnostic programs” in the Problem Determination and Service Guide).
If you have just added new software or a new optional device and the server is not working, complete the following steps before using the troubleshooting tables:
Chapter 5. Solving problems 63