Specifications

The following table contains the specifications for the ACCB-L, the ACCB-L-L1, and the ACCB-L-L2. The ACCB-L-L2 is not available pre-built from the factory, but is created by field-installing an ACCB-L2-PCK into a ACCB-L-L1 model.

Table 1-1Operational and Environmental Specifications for the ACCB-L, ACCB-L-L1, and ACCB-L-L2

 

ACCB-L

ACCB-L-L1

ACCB-L-L2a

Dimensions

33" (H) x 11" (W) x 8 3/4" (D)

33" (H) x 11" (W) x 8 3/4" (D)

This configuration is created

 

(84 cm x 28 cm x 23 cm)

(84 cm x 28 cm x 23 cm)

by field-installing an ACCB-

 

 

 

L2-PCK into an ACCB-L-

 

 

 

L1.

 

 

 

 

 

Weight

19 pounds (8.6 kg)

24 pounds (10.9 kg)

~2 pounds

 

 

 

 

 

Shipping Weight

23 pounds (10.4 kg)

27 pounds (12.2 kg)

~2 pounds

 

 

 

 

 

Operating Voltage

120/240 Vac,

120/240 Vac,

120/240 Vac,

 

60 Hz split-phase

60 Hz split-phase

60 Hz split-phase

 

 

 

 

 

Factory-installed

• Din Rail

• Din Rail

• Din Rail

hardware

• Ground Bar

• Ground Bar

• Ground Bar

 

 

• AC Bus Bar (Neutral)

• AC Bus Bar (Neutral)

 

 

• AC Bus Bar (HOT L1)

• AC Bus Bar (HOT L1)

 

 

• AC Input/Output Terminals

• AC Input/Output

 

 

• AC Bypass Breaker

Terminals

 

 

 

• AC Bypass Breaker

 

 

 

 

 

Factory-installed

None

#6 THHN AWG, rated to

#6 THHN AWG, rated to

wiring

 

105 °C, stranded copper

105 °C, stranded copper

 

 

• One - Ground Wire

• One - Ground Wire

 

 

• One - Neutral Wire

• One - Neutral Wire

 

 

• One - HOT IN

• One - HOT IN

 

 

• One - HOT OUT

• One - HOT OUT

 

 

 

 

 

Field-installed

N/A

ACCB-L2-PCK (needed to

• AC Bypass Breaker (Din

hardware

 

create ACCB-L-L2)

Rail-mountable) (w/HOT In

 

 

 

and HOT Out wiring)

 

 

 

• AC Bus Bar (HOT L2)

 

 

 

 

 

AC Bypass Switch

 

 

 

 

 

 

 

 

 

Bypass

None

60 Amp (SPST)

60 Amp (SPST)

 

 

 

 

 

Inverter

None

60 Amp (DPST)

60 Amp (DPST)

Input/Output

 

 

 

 

 

 

 

 

 

Rated Temperature

0 to 25 °C

0 to 25 °C

0 to 25 °C

 

(32 to 77 °F)

(32 to 77 °F)

(32 to 77 °F)

 

 

 

 

 

Storage

-55 to +100 °C

-55 to +100 °C

-55 to +100 °C

Temperature

(-67 to 212 °F)

(-67 to 212 °F)

(-67 to 212 °F)

 

 

 

 

 

Enclosure

Indoor rated, White,

Indoor rated, White,

Indoor rated, White,

 

Powdercoat Finish

Powdercoat Finish

Powdercoat Finish

 

 

 

 

 

 

 

 

 

 

1–4

973-0031-01-01 Rev A

Image 18
Contents Sine Wave Plus Long AC Conduit Box Owner’s Guide Page Sine Wave Plus Long AC Conduit Box Date and Revision Audience PurposeScope OrganizationConventions Used Abbreviations and AcronymsRelated Information Important Safety Instructions Explosive gas precautions CertificationsContents Operation Figures Page Tables Xii Introduction Introduction 1The Sine Wave Plus ACCB-L BasicACCB-L-L1 Specifications ACCB-L ACCB-L-L13ACCB-L Dimensions not to scale AC Bypass Switch Assembly For more information see , Operation in this guideBlockoff Plates 5Blockoff PlatesPage Installation Preparing for the Installation Installation Tools and MaterialsCode Compliance Configuration Planning Off-Grid ConfigurationsOn-Grid Configurations Pre-Installation Service PlanningLocation Ventilation Requirements 12 305 mm Required Shock Hazard Warning Label3Cover Removal and Replacement Removing and Replacing the CoverInstalling or Removing the Blockoff Plates 4The Blockoff Plate on the Long AC Conduit BoxKnockout Preparation 5SW Plus Inverter, AC Side Showing Knockout Location6Knockouts Locations Installing Additional Breakers 7Installing Additional Breakers on the DIN RailMounting Mounting on the Xantrex Back Plate XBP9Installing the ACCB-L on the Backplate Mounting on Plywood To mount the Long AC Conduit Box on plywoodWiring General Wire Sizes and Disconnect Requirements 1Torque Values for Wiring11ACCB-L Approved Internal Components 12ACCB-L-L1 Internal Components Factory installed Installation Wiring for Off-Grid Applications Single Inverter Configurations 120 VacInstallation Step-down Configurations 240 Vac to 120 Vac Installation Step-up Configuration Deep Well Pump 120 Vac to 240 Vac Dual Inverter Configurations 120 Vac and 240 Vac Wiring for On-Grid Applications 20Wiring an On-grid Application Using a Single InverterInstallation Step-up Configurations Utility Backup 120 Vac to 240 Vac Dual Inverter Configurations 120 Vac and 240 Vac Additional Accessory Wiring 24Accessory Wiring for Single-Inverter Configurations25Accessory Wiring for Dual-Inverter Configurations Operation AC Bypass Switch Operating the AC Bypass SwitchNormal Operation Bypass OperationDual Inverters 240 Vac Loads AC Input/Output OffWarranty and Return Information WarrantyDisclaimer ProductExclusions Return Material Authorization Policy Return ProcedureOut of Warranty Service Information About Your System Serial Number Purchased From Purchase DateIndex IX-2 Rev a Page Xantrex Technology Inc